SECTION 4
D.
Torch Trigger / gas Test Switch
The torch trigger positions are converted to mechanized logic on the mechanized consoles.
Operating modes:
Normal Pilot Arc (CENTER position) - The pilot arc will not re-strike automatically. Requires a new start signal. This
setting is recommended for standard plate cutting.
Continuous Pilot Arc (DOWN position) - The pilot arc will re-strike automatically. Examples for usage of this setting
are expanded metal and grate cutting.
Test Mode:
gas Test Switch (UP position) - The display screen will indicate flowing air pressure. The air regulator should be ad-
justed to recommended pressure before cutting operations. Allow air to flow for a few minutes. This should remove
any condensation that may have accumulated during shutdown period. Be sure to place switch in Normal Pilot Arc
(CENTER position) or Continuous Pilot Arc (DOWN position) before starting cutting operations.
E. Display Screen: Displays current settings during normal operation.
1. Power-up Indication: When unit is initially switched on the Model, PIP (Parts in Place), Software version will be
briefly displayed. Display will then show Current Setting.
2. gas Test: When unit is in the "GAS TEST" mode the display will indicate air pressure setting in psi/bar.
3. fault Indication: Should a fault condition exist in normal operation, the display will show a code number. Refer to
the "Help Code" menu on the front panel (non-"CE" units only) or in Section 4.1.F and in Troubleshooting Section 6.1.
Note:
figure 4-2. Powercut 1300/1600 Controls
140
OPErATION
E
UP position
CENTER position
D
DOWN position
Toggle Switch detail
F
(Codes shown on
Domestic (English) and
Bi-lingual (French-English)
units only)