Section 3 Installation; Installation; General; Equipment Required - ESAB Powercut-1300 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 465
SECTION 3
WArNINg
3.0

Installation

3.1

general

Proper installation is important for satisfactory and trouble-free operation of the Powercut cutting package. It is
suggested that each step in this section be studied carefully and followed closely.
3.2

Equipment required

A source of clean, dry air that supplies 500 cfh (236 l/m) at 90 psig (6.2 bar) is required for the cutting operation.
The air supply should not exceed 150 psig (10.3 bar) (the maximum inlet pressure rating of the air regulator sup-
plied with the package).
3.3

Location

Adequate ventilation is necessary to provide proper cooling of the Powercut. The amount of dirt, dust, and
excessive heat to which the equipment is exposed, should be minimized. There should be at least one foot of
clearance between the Powercut power source and wall or any other obstruction to allow freedom of air move-
ment through the power source.
3.4

Inspection

A.
Remove the shipping container and all packing material and inspect for evidence of concealed damage
which may not have been apparent upon receipt of the Powercut. Notify the carrier of any defects or dam-
age at once.
B.
Check container for any loose parts prior to disposing of shipping materials.
C.
Check air louvers and any other openings to ensure that any obstruction is removed.
400V CE Mains Supply requirements:
High power equipment may, due to the primary current drawn from the mains supply, influence the pow-
er quality of the grid. Therefore connection restrictions or requirements regarding the maximum permis-
sible mains impedance or the required minimum supply capacity at the interface point to the public grid
may apply for some types of equipment (see technical data). In this case it is the responsibility of the
installer or user of the equipment to ensure, by consultation with the distribution network operator if
necessary, that the equipment may be connected.
INSTALLINg Or PLACINg ANY TYPE Of fILTErINg DEVICE WILL rE-
STrICT THE VOLUME Of INTAKE AIr, THErEBY SUBJECTINg THE
POWEr SOUrCE INTErNAL COMPONENTS TO OVErHEATINg. THE
WArrANTY IS VOID If ANY TYPE Of fILTEr DEVICE IS USED.
NOTE !!!
109
INSTALLATION

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Powercut-1600

Tabla de contenido