Install Strain Relief
A
Install a UL listed/CSA approved ½" (13 mm) strain relief over one
of the knockouts (A) according to the selected discharge.
Mounting the Hood
1. Drill pilot holes on the thin area of the previously marked
keyhole slots with a ¹/
" (3 mm) drill bit.
8
2. Using 2 or more people, lift the hood into final position.
Feed enough electrical wire through the ½" UL listed or CSA
approved strain relief to make connections in the terminal
box. Tighten the strain relief screws.
3. Position the range hood so that the large end of the keyhole
slots are over the mounting screws. Then push the hood
toward the wall so that the screws are in the neck of the slots.
Install the .5 cm x 4.5 cm mounting screws in drywall anchors.
A
A. Mounting screws (4)
B. Security screws
4. Tighten the mounting screws, making sure the screws are in
the narrow neck of slots.
5. Tighten the security screws to the wall.
6. For direct wire installations, run the home power supply cable
according to the National Electric Code or CSA standards and
local codes and ordinances. There must be enough wiring
from the fused disconnect (or circuit breaker) box to make the
connection in the range hood electrical terminal box.
NOTE: Do not reconnect power until the installation is
complete.
OPTIONAL: If you prefer, bend the rear tabs against the rear
of the range hood and attach to the wall using #8- 4.2 x 16
mm truss-head screws.
B
Connect Vent System
1. Connect the vent work to the range hood.
2. Seal joints with vent clamps or duct tape to make secure and
airtight.
Check that the backdraft dampers work properly.
For recessed bottom cabinet only
If the cabinets have front, side or back trim, make 2 wood shims
the width of the trim and attach them to the cabinet bottom
recess on both sides.
See previous page for marking locations.
Wood shims
1. Cut holes at marked locations for duct and electrical wiring.
For the vertical duct, cut out
cabinet so you can move the duct freely when installing the
hood. It may also ease installation by cutting the hole 10¹⁄
instead of 10".
2. Drive a 4.5 x 13 mm screw (from the hardware packet)
partway into each center of the narrow neck of the keyhole
slots marked on the cabinet bottom.
3. Fix the wiring conduit to the hood.
4. Slide the hood back against the wall. Tighten the mounting
screws. Be sure the screw heads are in the narrow neck of the
keyhole slot. Connect ductwork to hood.
7
3
" extra toward the front of the
4
"
2

Publicidad