Descargar Imprimir esta página

Heiniger SIRIUS Manual De Instrucciones página 36

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 74
Malfunction
Motor is not running
Running time of a fully
charged battery is too
short and / or blades
are getting hot
No data displayed on
the charging status
display
The control light of
the charging station in
not on
When the battery is
flat the light of the
charging station does
not change from green
to red
18
Cause
Battery is dead
Contacts dirty
Faulty battery
Smell of burning from the
motor housing. Motor burned
out.
Faulty motor and / or electron-
ics
Clipper head blocked
Clipper blades were not oiled
sufficiently
Dead, not fully charged or
defective battery has been
used
Battery exhausted
Faulty battery
Charging station is not con-
nected to the power supply
Charging station is faulty
Contacts of battery and/or
charging station are dirty
Faulty battery
Battery exhausted
Contacts of the charging
station are deformed
Translation of the original instructions / Hair clippers
Rectification
Charge battery
Switch the clipper off and clean
the contacts of the clipper and the
battery
Replace battery
Have motor and / or electronics
replaced (S)
Have motor and / or electronics
replaced (S)
Clean and oil clipper head
Oil clipper blades
Only use intact and completely
charged original battery
Place the battery in the charging
station
Replace battery
Connect the charging station to the
power supply
Have charging station inspected (S)
Clean contacts
Replace battery
Place the battery in the charging sta-
tion for at least 20 minutes. Replace
the battery if the charging process
fails to start.
Have the charging station repaired
(S)

Publicidad

loading