Use the screw with the specified dimension to prevent
internal damage to the camera.
Connecting the RM-BR300 Remote
Control Unit
Use the RS-232C connecting cable supplied with the
Remote Control Unit.
1 2 3
1 2 3 4 5 6 7 8 9
IR SELECT
VISCA RS-422
OFF
ON
75
IN VISCA RS-232 OUT
EXT SYNC IN
VISCA RS-232C IN
RS-232C cable*
VISCA RS-232C
RM-BR300 Remote Control Unit
Note
When using the VISCA RS-232C connectors, check that
the BOTTOM switch on the bottom of the camera
(page 19) and the DIP switch on the bottom of the
Remote Control Unit (page 24) are set to RS-232C.
HD
SD
RGB/COMPONENT
DC IN 12V
VIDEO
S VIDEO
SDI OUT
to the AC adaptor
(supplied)
to the AC adaptor
(supplied with the
RM-BR300)
To connect the Remote Control Unit
using the VISCA RS-422 connectors
You can use the VISCA RS-422 connectors to connect
the RM-BR300 Remote Control Unit to the camera
instead of the VISCA RS-232C connectors. Use of the
VISCA RS-422 connectors allows the connection up to
1,200 m (3,937 feet) away.
Prepare the connecting cable using the RS-422
connector plugs that come with the camera and the
Remote Control Unit.
For making the cable, refer to the pin assignments of the
VISCA RS-422 connector (pages 86 and 87) and the
wiring diagram of VISCA RS-422 connection
(page 89).
For the use of the RS-422 connector plugs, see page 90.
1 2 3
1 2 3 4 5 6 7 8 9
IR SELECT
VISCA RS-422
OFF
IN VISCA RS-232 OUT
EXT SYNC IN
RM-BR300 Remote Control Unit
Notes
• When using the VISCA RS-422 connectors, check
that the BOTTOM switch on the bottom of the camera
(page 19) and the DIP switch on the bottom of the
Remote Control Unit (page 24) are set to RS-422.
• When the connections using the VISCA RS-422
connectors are made, the VISCA RS-232C connection
is not available.
ON
HD
SD
RGB/COMPONENT
75
DC IN 12V
VIDEO
S VIDEO
SDI OUT
to the AC adaptor
(supplied)
VISCA RS-422
VISCA RS-422 cable
VISCA RS-422
to the AC
adaptor
(supplied
with the
RM-BR300)
Connections
65