Controlling the Cooktop Burners:
To turn a cooktop burner on, push in on the control knob and turn left
(counter-clockwise) to the "LIGHT" position. Gas will flow and the igniters
on all burners will begin to spark. The small icon above the control knob
indicates the location of the burner being controlled. The various settings
(from OFF to HI) are located on the knob itself. After the burner ignites,
adjust to the desired heat setting by aligning the power level on the knob
to the indicator mark on the control panel. Most chefs will advise to
observe the flame, not the knob, while adjusting the burner setting. To turn
a burner off, simply rotate the control knob right (clockwise) to the OFF
position.
Icon on Control Panel
indicating which Burner
the knob controls
OFF
Burner Control is
"OFF"
Flame Characteristics:
Natural Gas: Burner flames should be soft blue in color and stable with no
yellow tips, excessive noise, or fluttering. (Occasional yellow flicker is
acceptable.)
LP Gas (i.e. Propane): Burner flames should be blue in color, with some
yellow at outer edge.
If flames are completely or mostly yellow, don't light evenly around burner,
or are accompanied by excessive noise or fluttering, contact a qualified
service provider for repairs. Some yellow streaking is normal during the
initial startup. Allow unit to operate 4-5 minutes and re-evaluate before
calling for service.
Yellow Flames
Call For Service
22
LIGHT
Burner Control is
Burner Control is
"LIGHT"
Yellow Tips on
Outer Cones
HI
MED
Burner Control is
"MED"
"HI"
Soft Blue Flames
Normal For Natural Gas
LO
Burner Control is
"LO"

Publicidad