Cleaning your VPULSE
To clean your VPULSE, please follow these simple
steps:
1. Remove electrical cord.
2. Fill the empty water container to the MAX fill
line with fresh, room temperature water. DO
NOT USE ANY CLEANING SOLUTIONS IN THE
WATER RESERVOIR AS THESE SOLUTIONS
COULD DAMAGE THE WATER PUMP AND
THERAPY PADS.
3. Replace the handle and connect power.
Connect all pads and enable all functions.
4. Operate the system for 10 minutes.
5. Empty the water reservoir.
6. Repeat these actions periodically.
Please use only the following cleaning agents
when cleaning the outside of your VPULSE
system: warm water with mild detergent, Lysol
70% isopropyl alcohol, Cidex
©
, or 10% bleach
solution.
Patients should not use cleaning or
decontamination methods different from those
recommended by the manufacturer without
first checking with the manufacturer that
the proposed methods will not damage the
equipment.
Care and Maintenance
• DO NOT store the pad in its shipping bag. The
shipping bag may trap the moisture remaining
in the pad.
• Store the VPULSE unit in a safe, cool and dry
place when not in use.
• Ensure the water container is empty of water
and dry to avoid bacterial growth and
contamination.
• Wipe down the device with a soft, damp cloth.
DO NOT use abrasive cleaner. NEVER immerse
the unit into any liquid.
• Keep away from all solvents and harsh deter-
gents. Please refer to cleaning instructions
prior to cleaning your VPULSE.
• DO NOT attempt to repair the VPULSE. There
are no patient-serviceable parts. Repair of the
system by an unauthorized person may void
the product warranty.
• To store, disconnect the electrical cord, the
tubing set and the pad.
16 of 23
Storage
1
Remove water from the Thermal-Compression pad by
rolling the pad up while still connected and squeezing
the water back into the Container.
©
,
2
Remove the Ice Bottles from the unit. Separate the
bottles and pour the water out, air dry.
3
Dump the water out of the side Control Unit so that the
control buttons and other electrical components
stay dry. When empty, let the unit "air dry" completely.
For long term storage, please use the shipping
materials and container supplied with the VPULSE.
Lysol
is a registered trademark of Reckitt Benckiser Inc.
®
Cidex
®
is a registered trademark of Johnson & Johnson Corp.
Warranty
Breg, Inc. warrants that this product is free from defects in workmanship, materials,
and fitness for use for 90 days from initial purchase under normal use for which it was
intended and under direct supervision of a licensed health care practitioner.
Breg, Inc.'s obligation under this warranty is limited to the replacement or repair of any
defective part or parts of this product. All expressed or implied warranties, including
the warranty of merchantability and fitness for a particular purpose, are limited to the
actual warranty period set forth above. No other warranty, express or implied, is given
and no affirmation of or by seller, by words or action, will constitute a warranty.
General Safety
This section is used to highlight certain operating
procedures and recommendations. Important
Safety Instructions / Read all instructions before
using.
The device should never be left unattended
when plugged in. Unplug from outlet when not
in use and before putting on or taking off parts.
No modification of this equipment is
allowed.
DO NOT use around flammable materials.
Close supervision is necessary when this
appliance is used near pets
The VPULSE pads are supplied non-sterile.
DO NOT sterilize these pads. Doing so may
compromise the functionality of the pad(s) and
may result in possible patient injury.
All VPULSE pads are intended for single
patient use and NOT intended for reuse or to be
washed or cleaned. Doing so may compromise
the functionality of the pad(s) and may result in
possible patient injury.
DO NOT lay on top of the pad connectors.
Doing so may result in patient injury.
DO NOT use pins or sharp objects to
secure the therapy pads or hoses. Doing so may
damage the system and compromise function.
The device is intended for single patient
multiple use.
DO NOT kink or sharply bend the tubing
set. Doing so may damage the system and
compromise the function.
Use this appliance only for its intended
use as described in this manual. DO NOT
use attachments not recommended by the
manufacturer. DO NOT use attachments from
other manufacturers. Connecting parts not
supplied by Breg will void the warranty and may
cause damage to the system and potential injury
to the patient.
Ensure the handle of the device is properly
installed and fully engaged prior to carrying the
system. For proper use, please reference the
handle locking and unlocking icons.
Use proper precautions in carrying the
device to avoid injury.
DO NOT carry this appliance by the supply
cord or use the supply cord as a handle.
When setting up the system, route the
supply cord and tubing set to avoid tripping and
to encourage ease of walking around the device.
DO NOT carry this appliance by the tubing
set or use the tubing set as a handle.
Keep the tubing set, the device and pads
away from heated surfaces.
Never operate the appliance without the
handle, the tubing set, and the pad(s) completely
connected.
Never operate the appliance with any foreign
objects (other than ice or Ice Bottles provided) in
the water reservoir.
.
17 of 23

Publicidad

loading