Nuova Simonelli CAFFETTERIA ITALIANA Instrucciones De Manejo página 52

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

ALARMS CAUSES
GROUNDS DRAWER
The coffee grounds count has reached the programmed
FULL
level.
GROUNDS DRAWER
The coffee grounds count has exceeded the program-
BLOCKED
med value by 10 units
OPEN DOOR
The electronic control unit has noted that the front door
is open.
UP. GR. MECH. T.O.
The upper motor mechanism has exceeded the maxi-
(UPPER GROUP
mum programmed time to reach the upper micro posi-
MECHANISM TIME
tion.
OUT)
LW. GR. MECH. T.
The upper motor mechanism has exceeded the maxi-
O. (LOWER GROUP
mum programmed time to reach the lower micro posi-
MECHANISM TIME
tion.
OUT)
UP. GR. MECH. T.O.
The lower motor mechanism has exceeded the maxi-
(UPPER GROUP
mum programmed time to reach the upper micro posi-
MECHANISM TIME
tion.
OUT)
LW. GR. MECH. T.
The lower motor mechanism has exceeded the maxi-
O. (LOWER GROUP
mum programmed time to reach the lower micro posi-
MECHANISM TIME
tion.
OUT)
SENSOR ALARM
The CPU has detected the closure of microswitches
which should not be closed at the same time during the
waiting phase
VOL. COUNT.
No impulses have arrived from the volumetric meter for
ALARM
a time exceeding 6 seconds.
(VOLUMETRIC
COUNT ALARM)
DELIVERY ALARM
The infusion has exceeded the maximum limit of 2 mi-
nutes. This alarm is the logical consequence of a non-
reset volumetric meter alarm.
SER. BOIL. LEV. AL. (SERVICE
The filling of the steam boiler has exceeded the imposed
BOILER LEVEL ALARM)
time limit of 60/90 seconds.
WATER PRES.
The CPU has detected that the pressostat which controls
AL.(WATER
the water is open.
PRESSURE ALARM)
COFFEE POIL. TEMP.
The temperature of the water in the coffee boiler (TEMC-
AL.(COFFEE BOILER
CAF) has exceeded the preset value (xx degrees over the
TEMP. ALARM)
programmed value).
UNIT. TEMP. AL.
The temperature of the coffee unit has exceeded the pre-
(UNIT TEMP.
set value (xx degrees over the programmed value).
ALARM)
COFFEE BOIL.
The activation of the water heating in the coffee boiler
HEAT. T.O.(COFFEE
(RISCCAF) has exceeded the established safety time-
BOILER HEATING
out. The time concerned is of 3 minutes when the tem-
TIME OUT)
perature measured is higher than the operating value
but lower than the programmed value.
If the temperature measured is between 5°C and the
operating value, the time out is 15 minutes.
UNIT HEAT. T. O.
The heating of the coffee unit has exceeded the establis-
(UNIT HEATING
hed safety time-out. The time concerned is of 3 minutes
TIME OUT)
when the temperature measured is higher than the ope-
rating value but lower than the programmed value.
If the temperature measured is between 5°C and the
operating value, the time out is 15 minutes.
MAINTENANCE
The machine has reached the preset number of cycles or
maintenance date
ANTI SC. FILT.
A 5 second sound alarm is provided at the end of each
MAIN. (ANTI
cycle when the alarm is present
SCALING FILTER
MAINTENANCE)
DATA MEM. AL.
The CPU has detected inconsistent data in the data me-
(DATA MEMORY
mory.
ALARM)
50
EFFECTS
RESET
10 selections involving coffee
With the machine on, remove the coffee grounds drawer, empty it and put it
are still possible.
back in place. This operation should take place in a time of not less than 7
seconds.
Blocks coffee selections, only
With the machine on, remove the coffee grounds drawer, empty it and put it
tea and milk functions are
back in place. This operation should take place in a time of not less than 7
available.
seconds.
The system blocks all the ope-
Close the door.
rations in progress.
Blocks the motor mechanism
Turning the machine off and then on again, the group POSITIONING CYCLE
is initiated. If the upper piston reaches the upper position, the alarm is reset;
otherwise the alarm is repeated and the lower piston is not activated.
Blocks the motor mechanism
Turning the machine off and then on again, the group POSITIONING CYCLE
is initiated. If the upper piston reaches the lower position, the tablet is expel-
led and the alarm is reset; otherwise the alarm is repeated and the lower pi-
ston is not activated.
Blocks the motor mechanism
Turning the machine off and then on again, the group POSITIONING CYCLE
is initiated. If the lower piston reaches the upper position, the alarm is reset;
otherwise the alarm is repeated and the upper piston is not activated.
Blocks the motor mechanism
Turning the machine off and then on again, the group POSITIONING CYCLE
is initiated. If the lower piston reaches the lower position, the alarm is reset;
otherwise the alarm is repeated and the upper piston is not activated.
Machine operation is interrup-
Turn power off, check the correct functioning of the unit microswitch move-
ted.
ment and turn the machine on again.
Only visualisation, the dose
Automatically, when the impulses resume, or by carrying out a new selec-
will cease automatically when
tion after having stopped the one in progress.
the 2 minute delivery time li-
mit has been reached.
Terminates the delivery in
Press button 0-1 or select a new dose.
progress.
Blocks the machine taking it
Press button 0-1: the machine initiates the "SWITCHING ON AND STARTING
back to OFF.
UP" procedure.
Indication on display.
Turn the machine off, check that the water pressure is not lower than the
specified value of the pressostat. Turn the machine on again and press but-
ton 0-1: the machine will initiate the "SWITCHING ON AND STARTING UP"
cycle.
If the machine is not connected to the water mains it is necessary to bypass
the pressostat
Blocks the machine taking it
Let the temperature return to within the allowed limits, then press button 0-
back to OFF.
1: the machine initiates the "switching on and starting up" procedure.
Blocks the machine taking it
Let the temperature return to within the allowed limits, then press button 0-
back to OFF.
1: the machine initiates the "switching on and starting up" procedure.
Blocks the machine taking it
Check the temperature probe and the heating element. Turn the machine on
back to OFF.
and press button 0-1: the machine will initiate the "SWITCHING ON AND
STARTING UP" cycle.
The machine remains in IDLE-
Turn the machine off, check the temperature probe and the heating element,
ON but the message COFFEE
then turn the machine on again and press the button 0-1: the machine ini-
UNIT HEATING ALARM re-
tiates the "switching on and starting up" procedure.
mains on the display; the se-
lection of doses is available
Alarm visualisation . The cof-
Resetting the machine cycles in the function "reading system data - mainte-
fees are made as usual, but
nance cycles" with key U/15 inserted.
the alarm message appears
on the display.
Alarm visualisation . The cof-
The number of the litres of water consumed by the machine can be reset in
fees are made as usual, but
the function "reading system data - maintenance cycles" with key U15 inser-
the alarm message appears
ted.
on the display.
The operation of the machine
Carry out the Preset procedure
is interrupted returning it to
IDLE-OFF
NOTES
1. Turning the machine off and then on again without emptying the grounds drawer will not re-
set the alarm.
2. If the pre-established value has not been reached and the grounds drawer is removed for
more than 7 seconds, the grounds count is reset to zero anyway.
A 1 second sound signal at the end of the cycle in progress is provided.
Once this alarm has been activated 10 more coffee selections can still be activated, after which
the machine will activate the GROUNDS DRAWER BLOCKED ALARM.
1. Turning the machine off and then on again without emptying the grounds drawer, will not re-
set the alarm.
2. If the pre-established value has not been reached and the grounds drawer is removed for
more than 7 seconds, the grounds count is reset to zero anyway.
A 1 second sound signal at the end of the cycle in progress is provided.
By closing the door the alarm is reset and the system returns to "0"- Machine OFF.
On opening the door, a 1 second sound signal is provided.
.
By setting the number of cycles at 0, the alarm will be disabled.
By setting a date well into the future, the alarm will not be activated.
There is a 5 second audible signal at the end of every cycle when the alarm is present.
By setting the number of litres to 0, the alarm is disabled.
There is a 5 second audible signal at the end of every cycle when the alarm is present.

Publicidad

Tabla de contenido
loading

Tabla de contenido