Operating Instructions
8
Disassembly
WARNING!
Risk of injury due to improper disassembly!
► Disassembly may only be carried out by authorized specialist personnel using suitable tools!
Risk of injury due to unintentional switching on of the system and uncontrolled restart!
► Secure the system against unintentional operation.
Sequence:
1.
Disconnect pneumatic connections.
2.
Disconnect electrical connections.
3.
Type RPC Positioner disassembly.
8.1
Disconnect pneumatic connections
DANGER!
Risk of injury due to high pressure.
► Before loosening lines and valves, turn off the pressure and vent lines.
1
2
1
3
► Disconnect pneumatic ports to the type RPC positioner.
No.
Designation
1
Pneumatic ports
2
Pneumatic connections
3
Actuator with valve
Type RPC D/PID positioner