Overview of service menu items
The following table provides an overview of the service menu items
reserved for Service.
Only the "energy management" functions that can be set and LED
display dimming are indicated below:
Left Rear
Meaning
Display (2RL)
C8
Maximum power
C9
Display LED Brightness Dimming
Power Limitation (Total Power Limitation) function
This function lets you set a total power limitation of all active cooking
zones in order to give a first constraint on the maximum absorption
of the hob.
This first power constraint can be set from 7 choices as shown in
the table.
This configuration must set while the hob is switched off (without
pressing the ON/OFF key (1), when connecting the hob to the
electrical mains or activating connection to the mains, within 2
minutes.
As default value C8 and 0, therefore with absorption constraint
7.4. It is still possible to enter the UO menu from the user menu, for
example, and adjust the power value from 7.4 to 1.4 with steps of
0.1 kW.
If for example the service menu C8 was set to level 7, therefore the
power setting from the user menu U0 would be adjustable from 2.8
up to 1.4 kW.
Proceed as follows:
• Press
which will flash only for the first 2 minutes after the
product is powered on
• Press and hold
(7); press, one at a time, all the Selection/
Display areas (2) of the cooking zones, counter-clockwise
starting from the front right zone as indicated in Fig. 29 (1-
>2FR... 2->2RR... 3->2RL... 4->2FL):
Variable
Front Left Display
(2FL) (Value
Format)
Yes
0,1,2,3,4,5,6,7
(C8 default=0)
Yes
0,1,2,3
(C9 default=1)
• A short beep will sound with each press.
• When all Displays (2) are pressed, the button can be released
.
Now:
• the Display (2) of the rear left zone (RL) will show the symbols
"C" and "0" in alternating sequence.
• You can now perform programming:
- Select the Display (2RL)
- Then slide on the Selection bar (4) until the symbols "C" and
"8" appear in the Display
- The following settable setting will appear on the Display (2FL):
0
7.4 kW (default setting)
1
6.0 kW
Note
Configuration already set:
0->7.4 kW (default)
1->6.0 kW
2->5.0 kW
3->4.5 kW
4->4.0 kW
5->3.7 kW
6->3.0 kW
7->2.8 kW
0->10%
1->25% (default)
2->40%
3->66%
Fig. 29
EN
19

Publicidad

loading

Este manual también es adecuado para:

Fhh 800 id tc bk