Descargar Imprimir esta página

Sony CBK-3620XS Instrucciones De Funcionamiento página 23

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 61
3
Attach the camera body adaptor
() and then attach the bottom
plate ().
Align and attach using the eight hex
screws, removed in step 1, and tighten
using a hex wrench (tightening torque
of 1.4 N·m).
Short
4
Attach the imager block adaptor
receiver to the camera body
adaptor.
Align with the index marks on the sides
of the receiver, and attach using the
two hex screws, and tighten using a
hex wrench (tightening torque of
1.4 N·m).
Index
mark
Removing from Camera
1
Remove the receiver from the
camera body adaptor.
2
Remove the camera body adaptor
from the camera body.
3
Remove the imager block from the
imager block adaptor.
Note
Orient the lens side face down when placing
the removed imager block on a flat surface.
If the heat sink side is placed face down, the
flange back distance (flange focal distance)
may change.
4
Attach the imager block, removed
in step 3, to the camera body
(tightening torque of 1.4 N·m).
Attaching to the Camera
Index mark
23

Publicidad