Descargar Imprimir esta página

Panasonic WV-CW960E Instrucciones De Funcionamiento página 19

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

WV-CW960_US 05.11.18 11:08 ページ19
CONNECTIONS
Precautions
• The following connections should be made by qualified service personnel or system installers in accordance
with all local codes.
• See the reverse side of the cover page for main lead connection.
• Turn off the power at the fuse box before starting the installation work, or it so could result in fire, electric shock,
personal injury, and material damage.
24 V AC (WV-CW964)
RS485 Data Port
Red
Data
Orange
Tx
Yellow
Data
Green
Rx
(RJ-12)
Alarm In/Out Ratings
Alarm In
: 5 V DC pull-up input. Drive capacity of at
lease 0.2 mA required.
OFF : 4 V DC minimum 5 V DC maximum,
or open
ON : 1 V DC maximum or short
Alarm Out : Open collector output. 16 V DC, 100 mA
maximum drive capacity
OFF : Open
ON : 100 mA maximum
* When connecting to an external device, set up the
system so the ratings are not exceeded.
Note: Do not turn off camera power within 30 seconds
after turning it on. Doing so can cause pan, tilt, zoom,
or focus to go out of position.
All manuals and user guides at all-guides.com
220 V - 240 V AC
(WV-CW960)
RS485 Data Port
(RJ-12)
Video Output
Coaxial Cable RG-6/U (5C-2V)*2
Connector
(BNC)
Alarm Input
Connector
8P Alarm Cable (provided)
Alarm Output
4P Alarm Cable (provided)
Connector
*1: For twisted pair cable, use shielded low-impedance cable with a thickness of at least AWG#22
(0.33 mm
).
2
*2: Keep the overall length of coaxial cable under 1200 meters (in the case of RG-6/U (5C-2V)).
*3: Be sure to connect the grounding cable to ground.
Alarm Input Connector
T(B)
T(A)
R(B)
R(A)
24 V AC Cable for camera
Twisted Pair Cable*1
Alarm Output Connector
Alarm In 1 (Black)
GND (Brown)
Alarm In 2 (Red)
GND (Orange)
Alarm In 3 (Yellow)
GND (Light Blue or Green)
Alarm In 4 (Blue)
GND (Violet)
• 24 V AC Power Supply Connection
Recommended wire gauge sizes for 24 V AC line
#24
Copper wire size
(AWG)
(0.22mm
Length
(m)
20
of cable
(ft)
65
(approx.)
Accessory Connector Information
Pin no.
Power source
1
24 V AC LIVE
2
24 V AC NEUTRAL
3
Ground
4
Not use
-19-
To Matrix Switcher,
etc.
To VIDEO IN port
(CAMERA IN)
To sensor, etc.
To buzzer,
display device, etc.
Alarm Out 1 (Grey)
GND (White)
Alarm Out 2 (Pink)
GND (Light Green
or Light Blue)
#22
#20
#18
)
(0.33mm
)
(0.52mm
)
(0.83mm
)
2
2
2
2
30
45
75
100
160
260
4
3
2
1

Publicidad

loading

Este manual también es adecuado para:

Wv-cw964Wv-cw960