3. Enter the desired duty cycle.
Using the numeric keypad or the knob and arrows, select a duty cycle value of 75. If you are using the numeric
keypad, press Percent to finish the entry. The instrument adjusts the duty cycle immediately and outputs a square
wave with the specified value (if the output is enabled).
Configure a Pulse Waveform
You can configure the instrument to output a pulse waveform with variable pulse width and edge time. The following
steps configure a 500 ms periodic pulse waveform with a pulse width of 10 ms and edge times of 50 ns.
1. Select the pulse function.
Press [Waveform] > Pulse to select the pulse function.
Keysight EDU33210 Series User's Guide
33