Setting The Bus Coupler Ddl Baudrate; Installation; Marking And Identification; Bus Coupler Mounting - Aventics DDL Instrucciones De Servicio

Ocultar thumbs Ver también para DDL:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

AVENTICS | DDL, DDL-E | 1987765499–BDL–001–AC
See figure 3
Baudrate

5.1.4 Setting the bus coupler DDL baudrate

All DDL participants have to set the same baudrate.
Die DDL-Baudrate wird am Schalter S2.1 eingestellt.
Tabelle 7:
Schalter S2.1 für die Baudrate
S2.1
Baudrate
OFF
DDL 125 kBaud
ON
DDL 250 kBaud (default setting)
6

Installation

6.1 Marking and identification

The address provided/used for the bus coupler is
inscribed on the bus coupler in the BTN field.

6.2 Bus coupler mounting

The bus coupler is placed on the multiple plug connector
of the valve system and screwed tight
Check the gasket to ensure it is intact and make sure
that it is in the correct position.
Applied voltage
Danger of injury from electric shocks.
Make sure the relevant system component is not
O
under pressure or connected to power when
electrically connecting modules to the valve
system.
Do not insert or disconnect plug connectors under
O
load.
CAUTION
47
Installation

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Ddl-e

Tabla de contenido