(A) automatic diameter and distance measuring arm
(B1) automatic width measuring arm (if present)
(B2) automatic width measuring ultrasonic sensor (optional)
(C) head
(D) display panel
(E) flange holder
(F) weight tray
(G) wheel support shaft
(H) cone holder
(J)
wheel guard
(L) wheel-holder shaft locking brake
(M) Control pedal C
On request, the wheel balancer can be set up by the manufacturer to operate with the power
supply available in the place of installation. The set-up data for each machine are given on
the machine data plate and on a special label attached to the power supply connection cable.
CAUTION
Any operations for hooking up to the workshop electrical board must be carried out only by
qualified technicians in compliance with the regulations in force, under the responsibility
and at the charge of the customer.
- The electric hook-up must be performed according to:
• absorbed power specifications indicated on the machine dataplate;
• the distance between the machine and the electric hook-up point, so that voltage drops
under full load do not exceed 4% (10% when starting up) of the rated voltage specified
on the data plate.
EM 9250 - EM 9250 C CompactLine Operator's manual
Main working parts (Fig. 8)
ELECTRICAL HOOK-UP
8
UK
87