7. Starting, operation
Assembly of DIN EN 17501-80 L-connector
(D) Mounting hole
1. Using the head of a small screwdriver in
the mounting hole (D), lever the terminal
block (6) out of the angle housing (5).
In order not to damage the sealing of the
angle housing, do not try to push the
terminal block (6) out using the screw
hole (1) or the cable gland (2).
2. Ensure that the conductor outer diameter
you select is matched to the angle housing's cable gland. Slide the cable through the cable
gland nut (2), washer (3), gland seal (4) and angle housing (5).
3. Connect the flying leads to the screw terminals on the terminal block (6) in accordance
with the pin-assignment drawing.
4. Press the terminal block (6) back into the angle housing (5).
5. Tighten the cable gland (2) around the cable. Make sure that the sealing isn't damaged
and that the cable gland and seals are assembled correctly in order to ensure ingress
protection.
6. Place the flat, square gasket over the connection pins on the top of the instrument
housing.
7. Slide the terminal block (6) onto the connection pins.
8. Secure the angle housing (5) and terminal block (6) to the instrument with the screw (1).
10
WIKA Operating instructions/Betriebsanleitung/Mode d'emploi/Instrucciones de servicio
GB
(1)
(2)
(3)
(5)
(4)
Female
connector
(6)
Sealing
Male connector,
Case with
pressure connection
A-10
7. Starting, operation
Specifications
Model A-10
Pressure ranges
bar
Over pressure safety
bar
Burst pressure
bar
Pressure ranges
bar
Over pressure safety
bar
Burst pressure
bar
MPa and kg/cm
{Absolute pressure: 0 ... 1 bar up to 0 ... 25 bar}
Pressure ranges
psi
Over pressure safety
psi
Burst pressure
psi
Pressure ranges
psi
Over pressure safety
psi
Burst pressure
psi
{Absolute pressure: 0 ... 15 psi up to 0 ... 300 psi}
Vacuum resistance
Fatigue life
Materials
Wetted parts
»
Pressure connection
»
Pressure sensor
Internal transmission fluid
Case
Power supply U
UB in VDC
B
Signal output and
RA in Ohm
maximum ohmic load R
A
WIKA Operating instructions/Betriebsanleitung/Mode d'emploi/Instrucciones de servicio
1
1.6
2.5
4
6
10
2
3.2
5
8
12
20
5
10
10
17
34
34
40
60
100
160
250
400
80
120
200
320
500
800
400
550
800
1000
1200
1700
2
are available
15
25
30
50
100
160
30
60
60
100
200
290
75
150
150
250
500
500
500
1000
1500
2000
3000
5000
1000
1740
2900
4000
6000
10000
2500
7975
11600
14500
17400
24650
As of 0 ... 10 bar
10 Mio. cycles
316 L
316 L (as of 0 ... 10 bar rel 13-8 PH)
Silicone oil (only with pressure ranges up to 0 ... 6 bar and
0 ... 25 bar abs)
316 L
8 ... 30 (14 ... 30 with signal output 0 ... 10 V)
RA ≤ (UB – 8 V) / 0.02 A
4 ... 20 mA, 2-wire
0 ... 10 V, 3-wire
RA > 10 k
GB
16
25
32
50
100
100
600
1200
2400
200
300
400
600
1500
1500
10000
17400
34800
11
A-10