(1) Prevents closing if pulse is maintained.
(2) Prevents closing and�or opening if pulse is
maintained.
During the opening manoeuvre, the
anti-crushing device causes an immediate
stop. During the closing manoeuvre, it opens
the door.
If, during closure, an obstacle is detected more than
three consecutive times, the automated system
considers this distance as the new closing contact point
and goes into closed status. To restore the correct
positions, remove the obstacle and command a new
cycle: at the next closure, the automated system will
advance at low speed until it detects the contact point.
9. COURTESY LIGHT
� The �ourtesy li�ht stays li�hte� �or � �inutes a�ter the en� o�
the �anoeu�re (�annot �e �o�i�ie�)�
Fig. 26
OTHER SAFETY DEVICES
10. CONNECTIONS
IMPORTANT: Before attempting any work on the board
(connections, maintenance), always cut off power.
� To pre�ent any ele�tri� noise whate�er� use separate sheaths
�or powerin� the network� si�nals an� a��essories�
� The ZODIAC 100 operator has a �a�le with a two�pole plu�
�or ���0 Va� power supply�
� To �onne�t the e�ternal �ontrols� sa�ety �e�i�es an� si�nals�
�reak open the pre�hole� ele�ent (Fi�� �6 re�� )�
� To �onne�t the sa�ety e��e (see par� 18���)� �reak open the
pre�hole� ele�ent (Fi�� �6 re�� )�
� Make the ele�tri�al �onne�tions� re�errin� to Fi�� ���
Inputs status leds:
LD
1
Input status OPEN
2
Input status STOP
3
Input status FSW
OPEN A
STOP
I� the STOP input is not use�� ju�per �onne�t the input
to the ter�inal
�
I� the photo�ells are not use�� �onne�t the FSW
input to ter�inal -TX FSW�
Meaning
OFF
Not enabled
Ena�le�
Sa�ety �e�i�es en�a�e�
The automated system stopped and at rest is indicated
in bold for each input.
ON
Ena�le�
Not Enabled
Safety devices disengaged
Fig. 27