As long as you keep the measurement button pressed (max.
120 secs), measurements are carried out in scan mode.
5. CONFIGURATION
5.1 DISPLAY
6. Degree symbol
7. Additional function display (see 5.2 – Plus)
8. Battery symbol
5.2 ADDITIONAL FUNCTIONS AND PROGRAMS
The EL range offers you a variety of useful additional settings.
These can be easily configured via the EL Range app or set
directly on the binoculars.
The following programs and additional functions are avail-
able:
- Track: Tracking Assistant for navigating to the last location
measured
- Comp: Compass calibration
- Plus:
Display of second line
- Second line inactive (OFF)
- Correction value in MOA
- Correction value in MRAD/MIL
- Correction value in cm
- Correction value in inches
- Number of clicks
12
EL RANGE / EN
1. Target mark
2. Distance measurement dis-
play (in meters or yards)
3. Display in meters (m) or
yards (y)
4. Compass symbol
5. Angle symbol
- Tilt angle
- Direction (compass)
- Adjusted shooting distance (CAL)
- Light: Individual brightness adjustment
- Atmos. data: Display of:
- Current temperature
- Current air pressure
Units:
Metric/imperial conversion
Rifle:
Firearm selection
Factory settings:
- Plus:
- Second line inactive (OFF)
- Light: - Brightness level 3
- Units: - Metric/imperial conversion
- Rifle:
- Firearm selection. Only possible once ballistics
have been configured
5.3 CONFIGURING THE BINOCULARS VIA THE APP
1. Install the EL Range app on your smartphone or tablet
2. Activate Bluetooth on your smartphone and the EL Range.
On the EL Range, press the measurement and mode
buttons simultaneously for 3 seconds until the status LED
flashes blue.
3. Connect the smartphone and the EL Range via Bluetooth.
To do this, select the serial number of your EL Range in the
app. You will find the serial number on the right eyepiece
adapter. You will need to lift up the right diopter adjustment
ring. Once you are connected, the blue status LED stays lit
up.
4. Now you can transfer the settings from the app to the EL
Range. The data from the last three measurements is also
transferred from the EL Range to the app. The app always
shows you the exact time of the last synchronization.
EL RANGE / EN