Summary of displays based on the confi guration:
Cool (HR140 = 3)
OFF
Relay OPEN
Relay CLOSED
Cool On = ON
1
3
2
4
Cool On Heat On
Cool On = OFF
SET
Notice: the confi gurations can be combined for complete control of the icons.
Power supply
Operating conditions
Storage conditions
Environmental pollution
Software class and structure
Casing ingress protection
Heat and fi re resistance category
Class of protection against electric shock
Period of electrical stress across the insulating parts
Immunity against surges
Temperature measurement accuracy
Humidity measurement accuracy
Max power consumption
Resistive load
Maximum load current
No. Description
E01 Reset data to factory values
E02 Status after blackout
E03 Backlight in standby
E04 Buzzer
E05 Communication address
E06 Maximum temperature set point
E07 Minimum temperature set point
E08 Internal temperature calibration
E09 Internal humidity calibration
E10 Frost protection
E11 Fan status when target temperature is reached
E12 Fan operating mode
E13 Fan circulation function option
E14 Fan circulation time
E15 Temperature diff erential
E16 Temperature unit of measure
E17 Humidity diff erential
E18 Maximum humidity set point
E19 Minimum humidity set point
E20 Serial port baud rate
E21 Serial port stop bits
E22 Serial port control bits
E23 Change menu password
E24 Relay output control
Summary table of operating parameters
"manuale thTx" +0300141IE rel. 1.0 - 16.01.2024
Temperature (Coil 70 = 0)
ON
OFF
Relay OPEN
Heat On = OFF
°F °C
%
3. TECHNICAL SPECIFICATIONS
Range
0÷99
0÷ 2
1 ÷5
0÷1
1÷207
0°C÷99°C
0°C÷99°C
-9÷9
-20÷20
ON/OFF
ON/OFF
0÷4
ON/OFF
1÷30 (Minutes) 5 (min) Set the fan circulation time per hour
0÷5
0 ÷ 1
1%÷20%
0%÷99%
0%÷99%
0÷3
0÷1
0÷2
0000÷9999
0÷1
Manual (Coil 51 =1)
Heat (HR140 = 4)
ON
Relay CLOSED
Heat On = ON
1
3
2
4
Cool On Heat On
°F °C
%
SET
Models TDB*******: 85~260 VAC 50/60 Hz
Models TDC*******: 24 VAC/DC (+10 to -10%)
0T55°C, 10 to <95% RH non-cond.
-20T60 °C
2
A
IP20
UL94-V0
to be incorporated in class I or II appliances
long
Category III
±0.5 °C
±5% rH
< 1W
≤ 3A
0.7 A
Def.
Notes
53
Default: 53, set to 55 and select the MODE button
1
0: the display is OFF.
1: the display shows the home screen.
2: the display shows the last status before the blackout.
4
-
0
0: Mute 1: On
1
-
37°C
-
5°C
-
0.0
-
7
Notice: the display
OFF
ON: Frost prot. On; 0F: Frost prot. Off
Range: 5.0°C to 8.0°C
Frost protection is only available during heating mode; when the temperature
drops to 5.0°C, frost protection is activated, while when the temperature is
above 8.0°C, frost protection is interrupted.
OFF
ON: Low speed 0F: Fan off
0
0: The fan operates and is visible in both heating and cooling modes
1: The fan operates in cooling mode but is not visible in heating mode
2: The fan operates in heating mode but is not visible in cooling mode
3: The fan is not visible in either heating or cooling mode, but the fan mode is
selectable
4: Heating and cooling modes only available (fan mode not visible)
OFF
ON: Low speed
OF: The fan is switched off
0.5
0
0: °C
1: °F
5%
-
70%
-
50%
-
2
0= 4800 bps; 1= 9600 bps;
2= 19200 bps; 3= 38400 bps
1
0 = 1 stop bit; 1 = 2 stop bits
0
0 = None; 1 = Odd; 2 = Even
0022
Range: 0000 to 9999
0
0: Temperature = Temperature control
1: Humidity = Humidity control
12
Humidity (Coil 70 = 1)
OFF
ON
Relay OPEN
Relay CLOSED
Water drop icon = ON
1
3
2
4
Cool On Heat On
Water drop icon
= OFF
SET
shows -20°C not -2.0
°F °C
%
Tab. 2.c
Tab. 3.a
Tab. 3.b