Descargar Imprimir esta página

Metz mecablitz 26 AF-1 digital Manual De Instrucciones página 101

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 132
10.2 Conditioning the flash capacitor
The flash capacitor built into the flash unit undergoes a
physical change when the device has not been used for
a long time. For this reason it is necessary to switch the
device every three months for approx. 10 mins.
The power supplies must deliver enough power so
that flash standby lights up no later than 1 min after
switching on.
11 Troubleshooting
Should it happen that the flash does not work as
specified, switch off the flash unit for about 10 seconds
using the
button. Check the camera settings and
make sure the foot of the flash unit is mounted correctly
in the camera's accessory shoe.
Replace the batteries with new or freshly charged
batteries.
The flash unit should function normally again once it is
switched back on. If this is not the case, contact your
local dealer.
Below is a list of some of the problems that may occur
when the flash unit is used. For each item, possible
causes and remedies for the problem are listed.
The AF measuring beam of the flash unit is not
activated.
• The flash unit is not ready for firing.
• The camera is not in „Single-AF (S)" or „ONE SHOT"
mode.
• The camera supports only its own internal AF measu-
ring beam.