Configuration Menu:
To set the parameter of Confguration Menu:
Press the Left Button [26] and the Right Button [25]
simultaneously to get the access of menu.
Turn the Left Knob [23] to choose the parameter.
Press the Right Button [25] to confirm the selection.
Turn the Right Knob [24] to choose the value of
parameter.
Press the Right Button [25] to confirm the selection.
Press the Left Button [26] to back to the previous
menu and confirm the chosen value.
Table 4. The default settings of Configuration Menu
Parameter
English
To exit the menu with changes saved, press the Left [26]
and the Right [25] Buttons simultaneously.
After one minute of inactivity the Menu without saving will
also exit.
Spot Timer – adjusts the time welding will continue even if
the trigger is still pulled. This option has no effect in 4-Step
Trigger Mode.
Crater Procedure – turn ON/OFF the Crater Settings
Procedure:
ON (factory default) – Crater can be adjusted. The Crater
Settings Procedure is assigned to the Right Button.
During adjusting Crater, the LED Indicator [25] lights.
OFF – The Crater Settings Procedure is OFF. After press
the Right Button, The Crater Settings Procedure is
ignored.
Preflow Time – adjusts the time that shielding gas flows
after the trigger is pulled and prior to feeding.
Factory default, Preflow Time is set at 0 seconds.
Adjust range: from 0,1 seconds to 25 seconds.
Postflow Time – adjusts the time that shielding gas flows
after the welding output turns off.
Factory default, Postflow Time is set at 0 seconds.
Adjust range: from 0,1 seconds to 25 seconds.
Arc/Loss Time – this option can be used to optionally shut
off output if an arc is not established, or is lost for a specified
amount of time. Error 269 will be displayed if the machine
times out. If the value is set to OFF, machine output will not
be turned off if an arc is not established nor will output be
turned off if an arc is lost. The trigger can be used to hot feed
the wire (default). If a value is set, the machine output will
shut off if an arc is not established within the specified
amount of time after the trigger is pulled or if the trigger
remains pulled after an arc is lost. To prevent nuisance
errors, set Arc Start/Loss Error Time to an appropriate value
after considering all welding parameters (run-in wire feed
speed, weld wire feed speed, electrical stick out, etc).
OFF (0) to 10 seconds (default = Off)
Note: This parameter is disabled while welding in Stick, TIG
or Gouge.
Screen
Brightness
brightness level. Adjust range from 1 to 10, where 5 is
default.
Feedback Persist – determines how feedback values are
displayed following a weld:
"Off" (factory default) – last recorded feedback values will
blink for 5 seconds following a weld, then return to
present display mode.
"On" – last recorded feedback values will blink indefinitely
following a weld until a Control or button is touched, or an
arc is struck.