OPERATION
9. Turn the relief valve to SPRAY (
Earth the gun by holding it against the edge of
the metal container while flushing. Failure to do
so may lead to a static electric discharge, which
may cause a fire.
10. Trigger the gun into the metal waste container until the
paint is flushed out of the hose and solvent is coming out
of the gun.
11. Continue to trigger the spray gun into the waste container
until the solvent coming out of the gun is clean.
For long-term, cold weather storage, or any
i
freezing temperature exposure pump mineral
spirits through the entire system.
For short-term storage not exposed to freezing
temperatures when using latex paint, pump
water mixed with Titan Liquid Shield through
the entire system (see Accessories section of this
manual for part number and product label for
dilution instructions).
12. Follow the "Pressure Relief Procedure" found in the
Operation section of this manual, section 4.5.
13. Store the sprayer in a clean, dry area.
Do not store the sprayer under pressure.
Attention
5.3
CLEANING UNIT FROM OUTSIDE
Never spray down the unit with a high-pressure
washer or high-pressure steam cleaners.
Do not put the high-pressure hose into solvents.
Attention
Use only a wet cloth to wipe down the outside of
the hose.
Wipe down unit externally with a cloth which has been
immersed in a suitable cleaning agent.
16
5.4
spray).
SUCTION FILTER
A clean suction filter always guarantees maximum
i
feed quantity, constant spraying pressure and
problem-free functioning of the unit.
1. Screw off the filter (Fig. 10) from suction tube.
2. Clean or replace the filter.
Carry out cleaning with a hard brush and an appropriate
cleaning agent.
PL3500 72V