Descargar Imprimir esta página

Titan POWRLINER PL 3500 72V Instrucciones De Uso página 21

Equipo de alta presión para pulverizar

Publicidad

Idiomas disponibles

Idiomas disponibles

PL3500 72V
7.3
OUTLET VALVE
1. Use a 22 mm wrench to remove the outlet valve from the
paint section.
2. Carefully remove the clasp (Fig. 17, pos. 1) using a
screwdriver. The compression spring (2) presses ball (4)
and valve seat (5) out.
3. Clean or replace the components.
4. Check the O-ring (7) for damage.
5. Check the installation position when mounting the spring
support ring (3) (clipped onto spring (2)), outlet valve seat
(5) and seal (6), refer to figure.
6. Torque the outlet valve housing to 60 Nm.
3
4
5
6
7
1
2
3
4
5
6
REPAIRS
21

Publicidad

loading

Este manual también es adecuado para:

24457302445730b2445730b2