4
System configuration
The control method of this product differs depending on the system configuration. Operate it following the methods
explained in the system configuration examples below.
• For the actual system configuration, ask your dealer or the installer of the product for information.
• Refer also to the installation manuals and owner's manuals of the remote controllers.
• If you use the central remote controller, refer also to its installation manual and owner's Manual.
System example
A. Heat recovery ventilation unit system
Heat recovery
ventilation unit
Remote controller
RBC-AW(M)SU5*
B. Heat recovery ventilation unit system linked with Air
conditioners
Outdoor
unit
Air
Air
Heat recovery
conditioner
conditioner
ventilation
unit
Remote controller RBC-AW(M)SU5*
77-EN
Operation
• The wired remote controller
If two remote
RBC-AW(M)SU5* can be used
controllers are used,
the start / stop of the Heat
the latter operation
recovery ventilation unit and the
overrides the former
ventilation fan speed and select
and their indications
ventilation mode.
always reflect the result
of the latter operation.
* Remote controllers other than
RBC-AW(M)SU5* are not
compatible with heat recovery
ventilation systems.
(Some functions cannot be
available.)
For how to use the remote
controller, refer to "6. How to use".
• The wired remote controller
If two remote
RBC-AW(M)SU5* can be used
controllers are used,
the start / stop of the Heat
the latter operation
recovery ventilation unit and the
overrides the former
ventilation fan speed and select
and their indications
ventilation mode.
always reflect the result
of the latter operation.
* Remote controllers other than
RBC-AW(M)SU5* are not
compatible with heat recovery
ventilation systems.
(Some functions cannot be
Heat recovery
available.)
ventilation
• In the case of Heat recovery
unit
ventilation unit system linked Air
conditioner, the type of
ventilation fan speed that you
can select from the remote
controllers are less than Heat
recovery ventilation unit ONLY
system.
• About separate operation of Air
conditioner and Heat recovery
ventilation, it is possible from
remote controllers RBC-
AW(M)SU5*.
* However, setting modifications are
required for separate control.
Contact your dealer for more
information.
– 39 –
C. Central control system
(When controlling the Air conditioner group and the Heat
recovery ventilation unit group separately)
Outdoor
unit
Notes
Air
conditioner
conditioner
Remote controller
RBC-ASCU1*,
RBC-AMTU3*,
RBC-AW(M)SU5*
D. Central control system
(When controlling the Air conditioners and the Heat
recovery ventilation units together)
Outdoor
unit
Air
conditioner
Remote controller RBC-AW(M)SU5*
NOTE
The heat exchange element may smell during the initial period of use. However, this is not a malfunction and the smell is harmless.
System example
Operation
• The central controller can be
used to start / stop the whole
system and separately start /
stop groups of Air conditioners
and the Heat recovery
Central controller
ventilation units. (In this system,
BMS-CT2560U*
the Air conditioners and the Heat
recovery ventilation units are not
linked in operation.)
• The functions that can control
Heat recovery ventilation from
central controller may differ
depend on the of central
Air
Heat recovery
Heat recovery
controller.
ventilation
ventilation
• The wired remote controller
unit
unit
RBC-AW(M)SU5* can be used
the start / stop of the Heat
recovery ventilation unit and the
ventilation fan speed and select
ventilation mode.
* Remote controllers other than
RBC-AW(M)SU5* are not
Remote controller
compatible with heat recovery
RBC-AW(M)SU5*
ventilation systems.
(Some functions cannot be
available.)
• The central controller can be
used to start / stop the whole
system. About separate
operation of Air conditioner and
Heat recovery ventilation, it is
impossible from central
Central controller
BMS-CT2560U*
controller, but possible from
remote controllers
RBC-AW(M)SU5*.
* However, setting modifications are
required for separate control.
Contact your dealer for more
information.
• The central controller cannot be
Air
Heat recovery
Heat recovery
used to control the Ventilation
conditioner
ventilation
ventilation
fan speed or ventilation mode of
unit
unit
the Heat recovery ventilation
unit.
* Central controller cannot recognize
Heat recovery ventilation. (Heat
recovery ventilation does not appear
in central controller.)
• The wired remote controller
RBC-AW(M)SU5* can be used
the start / stop of the Heat
recovery ventilation unit and the
ventilation fan speed and select
ventilation mode.
* Remote controllers other than
RBC-AW(M)SU5* are not
compatible with heat recovery
ventilation systems.
(Some functions cannot be
available.)
Notes
If three control devices
are used;
• About the central
controller and the
remote controllers for
Air conditioner or the
central controller and
the remote controllers
for Heat recovery
ventilation units, the
latter operation
overrides the former
and their indications
always reflect the
result of the latter
operation.
• About the remote
controllers for Air
conditioner and Heat
recovery ventilation
units are not affected
by each other's
operations.
If three control devices
are used;
• About the central
controller and the
remote controllers for
the Heat recovery
ventilation unit and
the Air conditioner,
the latter operation
overrides the former
regardless of which
device is used.
78-EN