23 TROUBLESHOOTING
Danger due to electrical voltage! Manipulating the machine with the power supply up
may result in serious injury or death. Before carrying out any troubleshooting work,
always disconnect the machine from the power supply and secure it against
unintentional recommissioning.
Many possible sources of error can be excluded in advance if the machine is properly connected to
the mains.
If you are unable to carry out necessary repairs properly and/or do not have the required training,
always consult a specialist to solve the problem.
Fault
Machine does not start
Machine does not reach
speed
Grinding wheel cannot
be switched on
Machine vibrates strongly
Grooves on the grinding
surface
Bad grinding result
HOLZMANN MASCHINEN GmbH www.holzmann-maschinen.at
WAR N I N G
Possible cause
Machine is not connected
Fuse or contactor broken
Cable damaged
Safety device not locked
Hydraulicsystem
Emergency stop button is pushed
Extension cable too long
weak power network
Hydraulic pump is switched off
Magnetic chuck is switched off
Stands on uneven ground
Motor mounting is loose
Grinding wheel is not balanced
Flange screw is loose
Grinding wheel badly dressed
Use unpropper grinding wheel
To much grinding abrasion
Feed of cross and longitudinal travel
Grinding table does not move easily
Surface of the magnetic chuck dirty
Coolant
TROUBLESHOOTING
Remedy
Check all electrical connections
Change fuse, activate contactor
Replace cable
Check grinding wheel guard, grinding
table guard, cabinet
Check oil level; fill in if necessary
Unlock the emergency stop button
Exchange to suitable extension cable
Contact electrician
Switch on the hydraulic pump
Switch on magnetic chuck
Level new
Tighten the fixing screws
Balance the grinding wheel
Tighten the flange screw
Dress the grinding wheel
Select suitable grinding wheel
Reduce grinding abrasion
Adjust speed
Check central lubrication, refill oil if
necessary or shorten lubrication
interval
Clean magnetic chuck
Switch on coolant pump, adjust
coolant supply
61