Descargar Imprimir esta página

V2 NUUR4 Manual De Instrucciones página 73

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 136
PARAMETER VALUE
Ft.tE
no
Si
CoS
no
Ch
Co.tE
no
rESi
Foto
SEn.v
0 - 7
SYnC
no
MAS
SLAv
Ev.di
Si
no
FinE
no
Si
DESCRIPTION
Test of the photocells
Function disabled
In order to achieve a safer operation for the user, the unit performs
a photocells operational test, before a normal working cycle.
If no operational faults are found, the barrier starts moving.
Otherwise, it will stand still and the flashing light will stay onfor 5
sec. The whole test cycle lasts less than one second
Safety ribbon input
This menu allows enabling the input for safety ribbon
Input disabled (ignored by the control unit)
Input enabled during closure and disabled during opening.
The intervention of the safety ribbon cause the reopening of the
barrier and the disactivation of any automatic closing
Test of the safety ribbons
This menu allows setting the method of control of the safety
ribbons working
Test disabled
Test enabled for conductive rubber safety ribbons
Test enabled for optical safety ribbons
Speed sensor
This menu allows adjustment of the sensitivity used to detect if the
barrier is blocked by an obstacle.
0
If set to
the obstacle is only detected when the barrier is
stopped.
When the sensor intervenes, the barrier stops and is operated in
the reverse direction for 3 seconds to remove the obstacle.
The next start command restarts the movement in the previous
direction
MASTER/SLAVE operation of the barrier for installations with
2 barriers
Single barrier
MASTER barrier - operation with 2 barriers
SLAVE barrier - operation with 2 barriers
Display of the events
If this function is enabled, every time that an event changes the
normal operation of the gate (coming into action of a safety, control
by user, etc.) the display shows a message indicating the cause.
Function activated
Function deactivated
End of Programming
This menu allows to finish the programming (both default and
personalized) saving the modified data into memory
Do not quit the programming
End of programming
DEFAULT
DEFAULT
MEMO
NUUR4
NUUR6
no
no
no
no
no
no
4
4
no
no
Si
Si
no
no
ENGLISH - 71 -