Error Code
ER 03 &
Constant
continuous
control unit is disrupted after
signal sound
10 seconds.
ER 20
Flash fault.
ER 21
Excessive temperature.
ER 22
Key evaluation fault. Control
unit is turned after 3.5 – 7.5
seconds.
ER 31
Configuration data is incorrect. -
ER 36
Temperature sensor error.
ER 40
Power supply is too low to turn
on the appliance.
ER 47
Communication
between the electronic board
configuration and the heaters.
U 400
Incorrect connection.
If the device is operated at maximum level for too long, it can turn off automatically.
This is an ordinary measure for safety of the device.
18
Error Description
use
of
buttons;
error
Potential Cause for
Error
Water
or
cooking
utensils
on the glass over the
control unit.
^ C error.
The
ambient
temperature
for electronics is too
high.
Short circuit or error in
detection of keys.
Short circuit or
electronic board
turns off.
Primary PTC is too hot. Disconnect the stove
No communication or
faulty communication.
Control unit is
connected incorrectly.
Solution
Clean the operating
surface of the stove.
Replace the electronic
board.
Allow the cooking
surface to cool down.
Check the temperature
verification
of
the
control
unit.
Replace the electronic
board.
New configuration is
required.
Replace the electronic
board.
from power supply
system.
Make sure that the
connection cable is
connected correctly
and functionally.
Connect the stove to
correct mains voltage.