Descargar Imprimir esta página

Lincoln Electric HARRIS PERFECTFLAME ST Instrucciones De Uso Y Seguridad página 19

Equipo de oxicombustible
Ocultar thumbs Ver también para HARRIS PERFECTFLAME ST:

Publicidad

Idiomas disponibles

Idiomas disponibles

Production Mode Operation - Follow the steps below to run in Production Mode.
WARNING: Oxygen and Fuel will begin flowing into the mass flow controllers (MFC) immediately. In order to
prevent damage to the MFCs, it is recommended that the unit not remain in Production Mode for extended
periods unless the attached torch is ignited.
Production Mode – Display Options
1. Press Production Mode on either the Main Menu or the Setup Menu.
2. Select the checkbox for the desired Job Setting. NOTE: only one Job
Setting may be run in Production Mode at any time.
3. Press Done to start brazing.
4. Ignite the torch. Actual fuel gas and oxygen flow rates as well as
calculated Flame Chemistry values will display on the screen.
WARNING: Fuel gas and oxygen flow rates cannot be
adjusted while the unit is running in Production Mode.
5. To stop the flame:
a. Use the shutoff valve on the torch
b. Press Active to stop gas flow. Press Idle to restart gas flow.
c. Press the Home icon if the system will not be in use for an extended
period of time.
6. To change to a new Job Setting (if available), press Select New Job. This
will cause all attached torches to shut off. Select a new Job Setting by
following the steps above starting at step 2. Once the new Job Setting is
selected, the torch can be re-ignited.
Fields that are displayed on the Production Mode screen may be disabled
and enabled by authorized users as needed. Follow the steps below to
change Display Options.
1. While in Production Mode, press Display Options. NOTE: the system
password is required to access this functionality.
2. Select the checkbox next to the field(s) you wish to hide. Select the
checkbox again to unhide. Press Display All to toggle all checkboxes
on the screen.
3. Press Save and Close to save and return to the Production Mode screen.
NOTE: The system will keep the selected display options, regardless of
the job being run, until they are changed.
19

Publicidad

loading

Este manual también es adecuado para:

Harris perfectflame mt43019464301945