SET UP & USE
Step 7: Mount indoor unit
If you installed new connective piping to
the outdoor unit, do the following:
1. If you have already passed the refrigerant
piping through the hole in the wall, skip
#2 & 3, and proceed to #4 below.
2. Otherwise, double-check that the ends of
the refrigerant pipes are sealed to
prevent dirt or foreign materials from
entering the pipes.
3. Slowly pass the wrapped bundle of
refrigerant pipes, drain hose, and signal
wire through the hole in the wall.
4. Hook the top of the indoor unit on the
upper hook of the mounting plate.
5. Check that unit is hooked firmly on
mounting by applying slight pressure to
the left and right-hand sides of the unit.
The unit should not jiggle or shift.
6. Using even pressure, push down on the
bottom half of the unit. Keep pushing
down until the unit snaps onto the hooks
along the bottom of the mounting plate.
7. Again, check that the unit is firmly
mounted by applying slight pressure to
the left and the right-hand sides of the
unit.
If refrigerant piping is already embedded in
the wall, do the following:
1. Hook the top of the indoor unit on the
upper hook of the mounting plate.
2. Use a bracket or wedge to prop up the
unit giving you enough room to connect
the refrigerant piping, signal cable, and
drain hose. (See illustration to the right)
3. Connect drain hose and refrigerant
piping (refer to Refrigerant Piping
Connection section on Page 25 of this
manual for instructions).
4. Keep pipe connection point exposed to
perform the leak test (refer to Electrical
and Gas Leak Checks section, Page 28
of this manual).
5. After the leak test, wrap the connection
point with insulation tape.
6. Remove the bracket or wedge that is
propping up the unit.
7. Using even pressure, push down on the
bottom half of the unit. Keep pushing
down until the unit snaps onto the hooks
along the bottom of the mounting plate.
UNIT IS ADJUSTABLE
Keep in mind that the hooks on the mounting
plate are smaller than the holes on the back of the
unit. If you find that you don't have ample room to
connect embedded pipes to the indoor unit, the
unit can be adjusted left or right by about
1.18"-1.96" (30-50 mm), depending on the model.