Chapter 9: General Radio Information
Failure Detections
Non-Certified RSM
9.5
Self-Diagnostics
The radio conducts self-diagnostic tests for every five minutes from the moment that the radio is turned on
until it is turned off.
Table 13: Self-Diagnostic Tests
Self-Diagnostic Tests
RSM Failure
Internal Over Temperature
Battery is at 50% or lower
9.5.1
Self-Diagnostics User Interaction
Table 14: Fire Safety Standard model Compliance Self-Diagnostics
Failure Detections
Antenna Failure
58
Hazard Zone Mode On
Radio Indications
●
Notification remains
until a certified
RSM is attached.
●
The display
shows Non-Haz-
ard Zone
Accessory At-
tached
Hazard Zone Mode On
Radio Indications
●
The display shows
Antenna Fail-
ure, and alterna-
tively changes to
ZoneChannel with
red background.
Hazard Zone Mode Off
Radio Indications
Description
●
Detects when the communication with the RSM
fails, or when the RSM is detached.
●
Detection occurs in Hazard Zone Mode or Non-
hazard Zone Mode.
●
Detects on Hazard Zone Mode RSM or adapter
only.
Detects when the radio, RSM, or battery is ex-
posed to a temperature level that exceeds the per-
mitted threshold.
Detects when the radio powers up with battery ca-
pacity of less than 50%.
Hazard Zone Mode Off
Radio Indications
●
The display shows
Antenna Fail-
ure, and alterna-
tively changes to
ZoneChannel with
red background.
Procedures
Remove the non-Fire
Safety Standard model
certified accessory from
the radio.
Procedures
Attach a certified Fire
Safety Standard model
antenna.