Descargar Imprimir esta página

Beninca BEVA.5 Manual De Instrucciones página 21

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 47
1) DESCRIPTION
Road barrier for passages up to 5m provided with built in control unit CP.EVA2 and quick external release for manual maneuver.
It is possible the synchronization of 2 motors for controlling 2 opposed barriers, to do this it is necessary to use the synchronization
control unit SIS (optional). Wire each other the two control units as shown in figure 16 and configure them as described in the paragraph
"Synchronization of two opposed barriers".
In addition to this it is possible the connection of two backup batteries by 12V 2,1Ah (DA.BT2), as shown in figure 14.
The barrier can work also in absolute absence of power supply by means of the accessory KSUN (sun system composed by solar panel,
backup batteries and control unit).
Every utilization different from the one described in this instruction manual is not allowed and voids the manufacturer warranty.
We would like to remind you that if you register on the site www.beninca.com you will have access to the technical documentation up-
dated for all the Benincà products and accessories and the guide for compiling the technical file and documents required under Annex
V of the Machinery Directive, mandatory under the regulations in force.
IMPORTANT: whether the barrier is used even for pedestrian passage it is compulsory to carry out the force test as indicated by the
European standard EN12445 (see the limitations as per the standard EN12453).
In case the passage is for vehicular use only, it is necessary to foresee appropriate signs of pedestrian prohibition.
2) DIMENSIONS
In figure 1 are shown the main dimensions of the EVA.5 barrier.
Overall dimensions are expressed in mm.
The road barrier length ranges from 3m minimum to 5m maximum.
As about 25cm are required to fix a road barrier, a useful opening of passage, ranging from 2.75m to 4.75, will be available, as shown
in Fig.1
Optional accessories can be fitted onto be barrier (photocells, selector, etc.). For assembly, apply the special covers supplied (Rif. A).
TAB.1
Accessories for use
EVA5.A
EVA5.A + VE.RAST
EVA5.A + VE.AM
EVA5.A + VE.RAST + VE.AM
EVA5.A + SC.RES
EVA5.A + SC.RES + VE.AM
Key
EVA5.A
Boom with bottom robber and bar light cover.
VE.RAST
Aluminium skirt.
VE.AM
Mobile support for bar.
SC.RES
Resistive safety edge (8K2).
Attention:
The installation of the VE.RAST interferes with the use of the SC.RES and vice versa.
The installation of the EVA.L lights kit does not influence the balancing of the bar
SPECIFICATION
Power supply
Motor power supply
Power drawn
Current absorption
Stand by current absorption
Torque
Opening time
Jogging
Protection class
Operating temperature
Noise
Lubrication
Weight
3
C
C
C
C
C
C
EVA.5
230Vac 50Hz
24Vdc
310 W
1,6 A
40 mA (230 Vac - 50 mA (115 Vac)
205 Nm
from 3,5 to 5 sec
Intensive use
IP44
-20°C / +50°C
<70 dB
Agip GR MU EP/2
55kg
EVA.5
Bar length (m)
3,5
4
C
B
B
B
C
B
B
B
B
B
B
B
4,5
5
B
A
A
A
B
A
A
A
A
A
A
A
C
B
A
21
EN

Publicidad

loading

Este manual también es adecuado para:

Eva.5