Enables or disables motors check.
TSTm
On: Check enabled. If the check has a negative result, no manoeuvre is commanded.
Off: Check disabled.
The code programmable transmitters is enabled or disabled.
On: Radio receiver enabled only for rolling-code transmitters.
Cvar
Off: Receiver enabled for rolling-code and programmable code transmitters (self-
learning and Dip Switch).
Selects the functioning mode of the boom light (24Vdc output on AUX2 or N.O. contact
on the output AUX 1 when configured at 2).
On: The boom light is off when the barrier is close, it turns on when the barrier is in
lBAR
movement or open.
On: The boom light flashes slowly when the barrier is close (1s pause), it flashes quickly
(0,5s pause) when the barrier is in movement or open.
The "forced opening in case of power cut-off" function is activated or deactivated (it
can be activated only with connected and operating emergency batteries).
On: Activated function. In the event of power failure, the control unit causes an open-
aopf
ing operation.
The barrier remains open until the power supply is back.
Off: Deactivated function.
Enables or disables remote radiotransmitters learning, as indicated in the paragraph
"Remote transmitters learning".
rem
On: Remote learning enabled.
Off: Remote learning not enabled.
MENU
By selecting this function, the receiver goes in waiting (Push) for a transmitter code to assign to the step-step function.
Press the key of the transmitter to assign to this function.
PP
If the code is valid, it is memorised and the message OK is displayed
If the code is not valid, the message Err is displayed
By selecting this function, the receiver goes in waiting (Push) for a transmitter code to assign to the OPEN function.
Press the key of the transmitter to assign to this function.
OPen
If the code is valid, it is memorised and the message OK is displayed
If the code is not valid, the message Err is displayed
By selecting this function, the receiver goes in waiting (Push) for a transmitter code to assign to the CLOSE function.
Press the key of the transmitter to assign to this function.
close
If the code is valid, it is memorised and the message OK is displayed
If the code is not valid, the message Err is displayed
By selecting this function, the receiver goes into waiting (Push) for a transmitter code to assign to the second radio channel.
Press the key of the transmitter to assign to this function.
2Ch
If the code is valid, it is memorised ad the OK message is displayed
If the code is not valid, the message Err is displayed.
ntx
By selecting this function the LCD screen shows the number of transmitters memorized into the receiver.
By selecting this function, the receiver goes into waiting (Push) for a transmitter code to erase from the memory.
CLR
If the code is valid, it is erased and the message OK is displayed
If the code is not valid or not present in memory, the message Err is displayed
Completely erases memory of the receiver. Confirmation of the operation is requested.
RTR
By selecting this function the receiver goes into waiting (Push) for a new PGM pressure to confirm the operation.
At end of erasing the OK message is displayed
Displays the number of complete cycles (open+close) carried out by the automation.
When the <PG> button is pressed for the first time, it displays the first 4 figures, the second time it shows the last 4. Example <PG>
0012 >>> <PG> 3456: made 123.456 cycles.
This function enables to activate the maintenance request notice after a number of manoeuvres determined by the installer.
To activate and select the number of manoeuvres, proceed as follows:
Press button <PG>, the display will show OFF, which indicated that the function is disabled (default value).
With the buttons <+> and <-> select one of the numeric values proposed (from OFF to 100). The values are intended as hundreds of
cycles of manoeuvres (for example: the value 50 indicates 5000 manoeuvres).
Press the OK button to activate the function. The display will show the message PROG.
The maintenance request is indicated to the user by keeping the indicator lamp lit up for other 10 sec after the conclusion of the
opening or closing operation.
26
RADIO (RADi)
CYCLES NUMBER (Nman)
MAINTENANCE CYCLES (maci)
FUNZIONE
(OFF)
(ON)
(OFF)
(OFF)
(OFF)