Descargar Imprimir esta página

Fein Slugger 7 273 Serie Instrucciones De Uso página 15

Publicidad

Idiomas disponibles

Idiomas disponibles

Filling the coolant container.
Prevent the flow of liquid along the cable into the socket outlet or into the
WARNING
core drill unit, as this can lead to electric shock. Tie a bow in the cable near
the plug, so that any liquid can drip off.
Do not use the magnetic core drill unit when the coolant-lubricant system is defective. Each
time before operating, check for tightness against leaks and for cracks in the hoses. Prevent
liquids from entering or penetrating electrical components.
Only use a coolant-lubricant emulsion (oil in water) as the cooling agent.
Observe the manufacturer's instructions on coolant.
Filling the dismounted coolant container
(figure 4)
Release the coolant container and remove it
from the magnetic core drill unit.
Unscrew the cap from the coolant con-
tainer.
Fill in pump-feedable cooling lubricant, e.g.
Slugger cutting oil.
Screw the cap onto the coolant container
again.
Mount the filled coolant container back on
the magnetic core drill unit.
Fig. 4
3.
2.
Upper closing cap
5.
Click!
6.
en
1.
4.
Coolant
container
6.
15