Trouble shooting
Note: The present operating mode cannot be
transferred to the permanent memory.
Code C8
Selecting the limit (threshold) value for suppression
of minor unbalance readings in grams, or
ounces. The unit of measurement (g or oz)
depends on the setting (
Grams:
Ounces:
Range 0.12 to 0.71 oz
Range 3.50 to 20.0 g
Pre-set value is 5.0* g
Factory-adjusted to 0.18* oz
Select another limit value, e. g.: 5.50 g
Select another limit, e. g.: 0.50 oz
• Select Code C8
• Select Code C8
• Set the value 5.50
• Set the value 0.50
• Press ENTER
• Press ENTER
Grams:
Ounces:
Range 3.50 to 20.0 g
Range 0.12 to 0.71 oz
Factory-adjusted to 5.0* g
Pre-set value 0.18* oz
Select another limit, e. g.: 5.50 g
Select another limit value, e. g.: 0.50 oz
• Select Code C8
• Select Code C8
• Set the value 5.50
• Set the value 0.50
• Press ENTER
• Press ENTER
Note: The selection is permanently acquired.
Code C11
Main shaft stop position.
The positioning brake stops the main shaft close to the
correction position by initiating pulsing braking.
The positioning brake is activated after switch on and
after a measuring run has been carried out and found
an unbalance greater than the limit value:
• Select Code C11
• Select one of the following options:
0 = No positioning brake after measuring run.
1*= Positioning brake after measuring run for left plane.
2 = Positioning brake after measuring run for right
plane.
Note: The selection is permanently acquired.
*