Physical installation
Warning! Read 'Safety information' on page 5 before installing the fixture.
To avoid head collisions when installing MAC Viper XIP fixtures next to each other,
allow a minimum center-to-center distance between fixtures of 704 mm (27.8 inches).
Martin can supply installation hardware such as rigging clamps and safety cables that are suitable for use
with the fixture (see the product specifications on the MAC Viper XIP product page on the Martin website
at www.martin.com).
Installation location
The MAC Viper XIP is designed for permanent or temporary indoor use or for temporary outdoor use. A
fixture with an IP54 rating can withstand rain and splashing water, but it cannot withstand high pressure
water jets or immersion in water.
Fasten the fixture to a secure structure or surface or stand it on a surface where it cannot be moved or fall
over. If you install the fixture in a location where it may cause injury or damage if it falls, secure it as
directed in this manual using a securely anchored safety cable that will hold the fixture if the primary
fastening method fails.
Installation environment
The fixture has a rugged construction and is designed to withstand temporary outdoor conditions.
However, it is not designed for use in extreme environments such as air with a high content of salt,
chlorine, acid or other aggressive agents. Exposure to harsh environmental conditions like these may
result in deterioration of the product that is not covered by the product warranty. If the fixture is exposed to
salt etc., rinse it carefully in pure water.
The fixture is designed and tested according to the IP54 standard. This means that the fixture is dust-
protected, not dust-tight. Ingress of dust is not entirely prevented, but it shall not enter in sufficient quantity
to interfere with the safe operation of the fixture. If the fixture is used in dusty or sandy environments,
cleaning will be required after use. Before using the fixture in a dusty or sandy environment, we
recommend that you replace the gauze air filters in the head with the disposable air filters with a paper
element that are available from Martin in sets of 12 (P/N 50400765). Air filter replacement takes no more
than a few seconds.
Avoiding damage from other light sources
Do not point the light output from other lighting fixtures at the MAC Viper XIP, as powerful light can
damage the display.
Standing the fixture on a flat surface
The fixture can be placed on a hard, fixed, flat horizontal surface provided that there is no risk that it may
cause an obstruction or be knocked over. Ensure that the surface can safely support the weight of all
items that will be placed on it, including any dynamic loads.
If you install the fixture in a location where it may cause injury or damage if it falls, secure it as directed in
this chapter with a securely anchored safety cable.
®
Martin
MAC Viper Safety and Installation Manual Rev. B