Descargar Imprimir esta página

Martin MAC Viper XIP Instrucciones De Seguridad E Instalación página 34

Publicidad

Idiomas disponibles

Idiomas disponibles

AC mains power
Warning! Read 'Safety information' on page 5 before connecting the fixture to AC
mains power.
The fixture has an auto-ranging power supply that accepts AC mains power at 100-240 V at
50/60 Hz. Do not apply AC mains power at any other voltage or frequency to the fixture.
The fixture's maximum current draw is as follows:
• At 100-120 V~: 11.0 A
• At 200-240 V~: 5.2 A
Typical half-cycle RMS inrush current: 17.0 A at 230 V, 50 Hz.
Typical earth-leakage current: 0.7 mA.
The fixture requires a power input cable with an IP65-rated Neutrik powerCON TRUE1 NAC3FX-W (TOP)
or equivalent female cable connector for AC mains power input. The cable must meet the requirements
listed under "Protection from electric shock" on page 6. Martin can supply suitable input cables with
connectors 1.5 m (4.9 ft.) or 5 m (16.4 ft.) long, as well as loose input connectors (see the Martin website
at www.martin.com).
The fixture can be hard-wired to a building electrical installation if you want to install it permanently.
Alternatively, you can connect it to local power outlets if you install a suitable power plug on the power
input cable. When installing a power plug, follow the plug manufacturer's instructions and connect the
wires in the power cable following the color coding guide in the table below:
US system
EU system
If you need to install a Neutrik powerCON TRUE1 (TOP) or equivalent IP65-rated connector on a power
cable, follow the connector manufacturer's instructions (normally published on the manufacturer's website
or included with the product), respecting the color coding guide above.
Linking fixtures to power in a chain at 100-120 V
If you are supplying the fixture with AC mains power at 100-120 V, do not connect any other MAC Viper
XIP fixture to the mains power OUT/THRU socket on the fixture's connections panel. Do not connect any
device to the mains power OUT/THRU that draws a current of more than 5 A.
Linking fixtures to power in a chain at 200-240 V
If you are supplying the fixture with AC mains power at 200-240 V, you can connect up to three (3) fixtures
in total to mains power in a linked daisy chain as follows:
1. Obtain a 12 AWG / 2.5 mm2 power input cable and 12 AWG / 2.5 mm2 power relay cables (available
from Martin – see the Martin website at www.martin.com).
2. Relay mains power from one fixture to another by connecting fixtures to power in a linked daisy-chain,
mains power OUT/THRU socket to mains power IN socket. This daisy-chain may contain up to a
maximum of three (3) fixtures total.
34
Live or L
Neutral or N
Black
Brown
®
Martin
MAC Viper XIP Safety and Installation Manual Rev. B
Earth, Ground or
White
Green
Blue
Yellow/green

Publicidad