If one or more of these factors is present, inspect fixtures within their first 100 hours of operation to see
whether cleaning is necessary. Check again at frequent intervals. This procedure will allow you to assess
cleaning requirements in your particular situation. If in doubt, consult your Martin dealer about a suitable
maintenance schedule.
Use gentle pressure only when cleaning, and work in a clean, well-lit area. Do not use any product that
contains solvents or abrasives, as these can cause surface damage.
To clean the fixture:
1. Disconnect the fixture from power and allow it to cool for at least 15 minutes.
2. Vacuum or gently blow away dust and loose particles from the outside of the fixture and air vents with
low-pressure compressed air. Holding cooling fan blades stationary with a screwdriver will protect
them from spinning too fast and possibly being damaged when you apply a vacuum or air jet.
3. Clean surfaces using warm water with a little detergent and a soft cloth, sponge or soft brush of the
type used for washing cars. Do not rub glass surfaces hard: lift particles off with a soft repeated press.
Dry with a soft, clean, lint-free cloth or low-pressure compressed air. Remove stuck particles with an
unscented tissue or cotton swab moistened with glass cleaner or distilled water.
4. Wipe the fixture with a soft, dry cloth after cleaning. We recommend that you apply power to the fixture
for a short time, which will allow it to warm up slightly and dry out completely, before putting it into
storage.
Cleaning air filters
The MAC Viper XP has two wire gauze air filters in the head (one on either side of the head) and two wire
gauze air filters in the base. When using the fixture in dusty conditions we recommend the use of head air
filters with paper elements. These are available as accessories in sets of 12 from Martin suppliers by
ordering P/N 50400765.
Head air filters
To service the head air filters:
1. Disconnect the fixture from power and allow to cool for 30 minutes.
2. Position the head pointing upwards so that the head air filter covers are accessible.
3. See illustrations below. Release the latches (arrowed) and remove the two head air filter covers, one
on each side of the head. Remove the air filters from their recesses in the head.