Hofmann geodyna 8200 Manual De Operador página 74

Tabla de contenido

Publicidad

74
5-15
5-16
5-17
5-18
Operation
5.8
AUTOMATIC Mode "BALANCE
WITH RUN OUT"
The following instructions describe the specific
functions of the balancer in the "BALANCE WITH RUN
OUT" mode.
Icon shown in (Fig. 5-15) identifies active "BALANCE
WITH RUN OUT" mode. The unit runs in automatic
mode.
This mode allows operator to measure wheel and rim
run-out by means of laser scanners (Fig. 5-16).
Two different measuring options can be set through
the setting panel (Fig. 5-17).
If user sets "Rim run-out measurement" to "Limit
exceeded" (Fig 5-17), the machine will only run
wheel measurement - and rim will be measured, too,
only if the value set for "Wheel radial run-out limit (1
Harmonic)" is exceeded.
If user sets "Rim run-out measurement" to "ALWAYS"
(Fig 5-18), the machine will measure both wheel and
rim.
st

Publicidad

Tabla de contenido

Solución de problemas

loading

Tabla de contenido