BIEMMEDUE FIRE 45 Manual Para El Usuario página 13

Generador de calor por rayos infrarrojos
Tabla de contenido

Publicidad

You can run the generator in manual by setting switch (14) to
ON.
The generator can only work automatically when a control
device, such as for example a thermostat or a timer, is connected
to the generator.
Connection to the generator is made by removing the socket
cover (15) and inserting the thermostat plug.
To start the machine you must:
• if connected to the thermostat, turn the switch to (ON + );
• if not connected to the thermostat, turn the switch to (ON);
For the -2 or -2 SPEED models it is possible to select the
thermal power level, by turning the switch (18) to the first stage
position (I S) or to the second stage (II S): the corresponding
levels of heat are contained in technical Table I.
When unit is started for the first time or is started after the oil
tank has been totally emptied, the flow of oil to the burner may be
impaired by air in the circuit. In this case the control box will cut
out the heater and it might be necessary to renew the starting
procedure once by depressing the reset button (13).
Should the heater not start, check that oil tank is full and
depress reset button (13).
Should the heater still not work, please refer to chapter
"OBSERVED FAULTS, CAUSES AND REMEDIES".
Warning
Never stop the machine by unplugging the
electrical plug: this could cause overheating.
STOPPING THE HEATER
Set main switch (14) on "0" position or turn thermostat or other
control device on lowest setting.
The flame goes out and the fan continues to work for approx.
90 sec. cooling the combustion chamber.
TRANSPORT
Warning
Before making any attempt to restart heater find
and eliminate reason of overheating.
EN
Before heater is moved it must be stopped and unplugged.
Before moving the heater wait till it has totally cooled off and
make sure oil tank cap is securely fixed.
Warning
During handling and transport gas oil may leak:
the tank fuel cap cannot guarantee sealing to allow
the introduction of air and tank emptying during
machine operation.
For handling in short to medium distances, it is enough to grab
the generator by the handle and roll it on its wheels. In case of
need, the generator can be lifted using ropes or chains secured
to the hooks (19) provided on the machine. In this case it is
always best to ensure that the ropes and/or chains are securely
hooked and that they are intact and stably in place before
handling.
MAINTENANCE
Preventive and regular maintenance will ensure a long trouble
free life to your heater.
Warning
Never service heater while it is plugged in,
operating or hot.
Severe burns or electrical shock can occur.
Every 50 hours of operation: disassemble filter and wash with
clean oil, remove upper body parts and clean inside and
ventilator with compressed air, check correct attachment of H.T.
connectors to the electrodes and check H.T. cables, remove
burner assembly, clean and check electrode settings, adjust
according to scheme "REGULATION OF ELECTRODES".
13

Publicidad

Tabla de contenido
loading