Enter the programming menu (See Page 16) and go to the PRG2 function.
VARIABLES
PH SETTINGS
SET
ALL
ALH
REL
PRS
DEL
SPM
BP
REG
OUT
PER
MON
DB
RMA
PHS
PHE
CHLORINE SETTINGS
SET
ALL
ALH
REL
PRS
DEL
SPM
BP
REG
OUT
PER
MON
DB
RMA
CLS
CLE
CTP
CPH
ENABLING
EN
ID
BR
Time-related proportional control enables any changes in the measurement to be followed up
rapidly, optimising the metering in relation to the distance from the set point.
PERMISSIBLE LIMITS
7,20 pH
6,50 pH
7,90 pH
ACID
NO
0 Seconds
20 Strokes/min.
0,50 pH
PROP
MIS
500 Seconds
0 Seconds
0 % of BP
4-20 mA
0 pH
14,00 pH
0.60 ppm
0.30 ppm
1.50 ppm
LO
NO
0 Seconds
20 Strokes/min
0.50 ppm
PROP
MIS
500 Seconds
0 Seconds
0 %di BP
4-20 mA
0 ppm
14.00 ppm
0 %/°C
OFF
SC
1
2400
DEFAULT VALUES
SET POINT pH
PH minimum alarm
PH maximum alarm
Type of control
Status of the pH relay
Delay time, pH metering
Strokes/minute, Output
Freq.
Proportional band
Control mode
Working mode Output mA
Period (Reg. Prop.)
Minimum ON time
dead band (reversed
hysteresis)
MA output dynamics
Initial value for mA control
End value for per mA
control
SET POINT Chlorine
Chlorine minimum alarm
Chlorine maximum alarm
Type of control
Status of chlorine relay
Chlorine-metering delay
time
Strokes/minute, Output
Freq.
Proportional band
Control mode
Working mode Output mA
Period (Reg. Prop.)
Minimum ON time
dead band (reversed
hysteresis)
MA output dynamics
Initial value for mA control
End value for per mA
control
Coefficient for offsetting the
measured value in relation
to the temperature
expressed in %/°C.
Enables correction of the
chlorine measurement in
relation to the pH
Enables the Cal and Set
keys
Indicates the ID of the multi-
point serial network
Baud rate of RS485 serial
link
COMMENTS
23