This type of control is recommended in well mixed systems, and enables a good level of control. It
is very suitable for controlling both the pH and the chlorine.
One the length of the modulating period of Ton and of Toff has been chosen, it is advisable to keep
an eye on the measurements for the first working period, in order to optimise the times.
The minimum Ton value of MON enables the SET POINT to be approached with a degree of
metering sufficient to exceed it. Otherwise, the pump might always run at the minimum in the
vicinity of the set point, without ever stopping.
Example:
If the following values are set, proportional control in time will be obtained with a minimum Ton of
the metering pump in the region of the Set Point.
VARIABLES
PH SETTINGS
SET
ALL
ALH
REL
BP
REG
OUT
PER
MON
Note: It is not possible to set both the hysteresis (HIS) and the delay time (DEL) for activation of
the pump.
CHLORINE SETTINGS
SET
ALL
ALH
BP
REG
OUT
PER
MON
PERMISSIBLE LIMITS
7,20 pH
6,50 pH
7,90 Ph
ACID
0,20 pH
PROP
MIS
20 Seconds
3 Seconds
1.00 ppm
0.60 ppm
1.50 ppm
0.20 ppm
PROP
MIS
20 Seconds
3 Seconds
DEFAULT VALUES
SET POINT pH
PH minimum alarm
PH maximum alarm
Type of control
Proportional band
Control mode
Working mode Output mA
Period (Reg. Prop.)
Minimum ON time
SET POINT Chlorine
Chlorine minimum alarm
Chlorine maximum alarm
Proportional band
Control mode
Working mode Output mA
Period (Reg. Prop.)
Minimum ON time
COMMENTS
24

Publicidad