Cover Removal and Replacement

Inspect the cover for damage and replace if necessary.
Note: Keeping a cover on your cushion will help to protect the cushion components. A cover will also help to
keep the air cells together, which may aid in slide board transfers.
Cover Removal: Unzip and remove the cover from the cushion.
Cover Replacement: Turn the cover and the cushion upside down:
The non-skid material should face up and the zipped opening
should face you. The air cells should face down. Insert the cushion
into the cover, following the instructions below.
Standard Cover Instructions
The back of the cushion should face the zipper.
Make sure all four corners of the cushion extend
through the corner openings in the cover.
Carefully pull the inflation valve and the Yellow
Rope through the openings.
Close the zipper completely. Turn the cushion
over so the air cells face up. The cushion should
lie flat inside the cover with the non-skid
material on the bottom and all cells covered.

Troubleshooting

For additional assistance, contact your equipment provider, distributor, or Customer Support.
Not Holding Air
Inflate the cushion. Inspect the inflation valve(s) and hose(s) for damage.
Confirm that the inflation valve is completely closed. Look for holes in the
cushion. If very small holes or no holes are visible, follow the instructions in the
Repair Kit provided with your product. For inflation valve or hose damage, or
for large holes or leaks in the cushion, see the Limited Warranty supplement, or
contact Customer Support.
Not Able To
Confirm that the inflation valve is open. Inspect the inflation valve(s) and
Inflate or
hose(s) for damage. When inflating SELECT Cushions: Confirm that the green knob
Deflate the
of the ISOFLO Memory Control is pushed toward the center of the ISOFLO in the
Cushion
UNLOCKED position so that all chambers will inflate.
Uncomfortable
Confirm that:
or Unstable
Allow the individual at least one hour to adjust to the cushion.
The Cushion
Make sure the non-skid bottom of the cushion cover is facing away from the
Slides on the
individual. Use directional labels on the cushion and on the cover to orient the
Wheelchair
cushion.
to the wheelchair.
ROHO DRY FLOATATION Wheelchair Cushions Operation Manual
- the cushion is not underinflated or overinflated (See Cushion Adjustment.)
- the cushion cells and the top of the cover are facing up.
- the cushion is centered beneath the individual.
- the cushion is properly sized to the individual and the wheelchair.
When possible,
Hook fasteners are available upon request.
Heavy Duty Cover Instructions
The front of the cushion (the inflation valve)
should face the zipper.
Tuck the inflation valve and the Yellow Rope
inside the cover.
Close the zipper completely. Turn the cushion
over so the air cells face up. The cushion should
lie flat inside the cover with the non-skid
material on the bottom and all cells covered.
use hook and loop fasteners to further secure the cushion
8
Refer to the label on the
bottom of the cushion
and to the image on the
cover to correctly orient
your cushion and cover.