Candy TRIO 9501 Manual De Instrucciones página 7

Ocultar thumbs Ver también para TRIO 9501:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 53
&+$1*,1* 7+( *$6 7<3( 
WKH FDORULILF FDSDFLW\ DQG SUHVVXUH RI WKH JDV YDU\ DFFRUGLQJ WR WKH W\SH RI JDV
:KHQ FKDQJLQJ WKH JDV WKH WHFKQLFLDQ VKRXOG VXFFHVVLYHO\  FKDQJH WKH MHWV PDNH WKH JDV FRQQHFWLRQ WR WKH LQVWDOODWLRQ DQG VHW WKH
PLQLPXP IORZ RI DOO WKH JDV EXUQHU WDS
%*#0)+0) 6*' )#5 6;2'
Factory setting :
Natural gas = G20-20 mbar/G25-25 mbar
Gas setting possible according to installation
Butane gas G30-29 mbar or Propane gas
G 31-37 mbar
%*#0)+0) 6*' ,'65 1( 6*' )#5 $740'45
Hob burner jets
To gain access to the jets :
- lift the hob lid,
- remove the top, grills, caps and
heads of all burners,
- use a tube spanner (7) inside the
burner,
- according to the information given
in the table, install jets suitable for
the burner type and gas type
supplied.
For reinstallation, fit the heads,
burner and top grills.
5'66+0) 6*' +&.' (.#/'
If the gas type has been altered, the stability of the flame in the minimum flow
must be checked and set by adjusting the by-pass screw.
To access the top burner by-pass screw, remove the control panel knobs.
a) Butane- propane gas :
the setting is done by screwing right in (without forcing) the by-pass screw
whose calibrated hole provides the minimum flow.
b) Natural gas :
- unscrew the by-pass screw one turn,
- replace the knob, light the burner and set to low flame,
- remove the knob again, screw the by-pass screw until a
reduced flame is obtained, staying stable when going from high to low position.
- replace the knob.
INSTALLATION
CAT.
II 2E+3+
BE-FR
II 2H3+
CH-ES-GB
IT-PT
II 2H3B/P
CZ-DK-FI
NO-SE
II 2H3B/P
HU
I 2E
DE
II 2L3B/P
NL
II 2ELs3B/P PL
Each jet is identified with a mark.
BURNER
JET
G20 20 mbar
G20 25 mbar
G25 25 mbar
G30 29 mbar
G31 30 mbar
G31 37 mbar
 *%
GAS/GAZ/Pression (mbar)
G20/20 G20/25 G25/25 G30/29 G30/36 G31/30 G31/37
$8;,/,$5<
6(0,5$3,'
Front right
Rear left
Front left
kW
kW
Jet
Jet
Jet
1,00
1,75
1,20
2,00
76
101
118
0,90
1,60
1,00
1,75
50
0,90
66
1,60
80
1,00
1,75
By-pass screw
Warning :
Never loosen
the others
screws !
G350/13
5$3,'
8/75$5$3,'
Resr right
kW
kW
Jet
2,50
3,50
2,80
4,00
144
2,30
3,20
2,50
3,50
2,25
94
3,20
2,50
3,50

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Trio 9503

Tabla de contenido