2. Push the battery into the battery holder until it engages with an audible click.
3. Check that the battery is seated securely.
5.3

Removing the battery

1. Press the battery release button.
2. Remove the battery from the device.
6
Operation
Observe the safety instructions and warnings in this documentation and on the product.
6.1

Preparing and pairing layout tool and tablet

The tablet has to be paired to the layout tool only once, when the two are used together for the first time.
1. Position the layout tool on the floor at a point with the best view of the working area.
2. Switch the layout tool on.
3. Switch the tablet on and open the "PMD 200" app.
4. Accept the End User License Agreement.
5. Accept the use of location services.
6. Pair the layout tool with the tablet by selecting the layout tool with the appropriate serial number in the
app.
The product's serial number is on the rating plate affixed to the back of the head.
The settings are saved so that they can be retrieved the next time the layout tool is used. Tablet
and layout tool pair with each other automatically.
7. Wait until the layout tool has leveled itself automatically.
6.2

Creating new layout

When you start a new layout, the data of the last layout are irrevocably deleted.
1. On the app's start screen, select New layout.
2. If you want to resume working on your last layout, select Current layout on the start screen.
6.3

Defining control line

You have to measure out a control line before you can start setting out your layout.
The ways in which you can define a control line are as follows:
Measure two points on a control line or on a building axis.
Measure two points on a building wall or on building columns.
The rule of thumb for the control line is: The radius of the working range is roughly twice the length of
the measured control line.