Inspecting And Cleaning The Drain Siphon; Inspecting And Cleaning The Fi Ll Solenoid Valve; Checking The Washing/Emptying Cycle For Humidisk 65 - Carel huniDisk Serie Manual Del Usuario

Humidificador centrífugo
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

6.2 Inspecting and cleaning the drain siphon

The drain siphon may need to be cleaned periodically: the accumulation of dirt inside the siphon may
compromise operation.
When cleaning is required, proceed as follows:
6.2.1 humiDisk
(Fig. 6.c)
10
• remove the air fi lter;
• remove the hose T from the tube R;
• unscrew the screws V;
• remove the tube R;
• clean both the tube R and the tube S, inside the tank;
• after cleaning replace all the parts.
(Fig. 6.d)
6.2.2 humiDisk
65
• remove the air fi lter;
• slide out hose B from the drain siphon A;
• unscrew the screws C;
• remove component A;
• clean both part A and the hole it is inserted into, then reposition.
6.3 Inspecting and cleaning the fi ll solenoid valve
The fi ll solenoid valve is fi tted with an inlet fi lter that must be checked and cleaned periodically.
6.3.1 humiDisk
(Fig. 6.e)
10
To access the fi lter, unscrew the fi tting A on the supply hose: the fi lter is found inside the threaded bushing
E on the solenoid valve.
If cleaning becomes too frequent, install a cartridge fi lter on the appliance water supply line (see: paragraph
2.7 and Fig. 2.z).
6.3.2 humiDisk
(Fig. 6.f)
65
To reach the fi lter, unscrew the fi tting A on the supply hose: the fi lter is found inside the threaded bushing
B on the solenoid valve.
If cleaning becomes too frequent, install a cartridge fi lter on the appliance water supply line (see: paragraph
2.7 and Fig. 2.z).
6.4 Checking the washing/emptying cycle for humiDisk
• Check that the cycle is performed periodically.
To do this, proceed as follows:
• Remove the end of the drain hose not attached to the appliance and insert it into a container to collect
the water that is drained.
• Stop the humidifi er by turning off the control humidistat: this starts the washing cycle.
If the cycle does not continue normally, the water basin and the drain siphon must be cleaned.
IMPORTANT: the humiDisk
is an air humidifi er, and so any other use that the unit is not intended for (for
65
example spraying insecticides, disinfectants, perfumes or any product other than water) may be dangerous
or affect the correct operation of the appliance.
humiDisk - +030222022 - rel. 2.1 - 01.03.2012
65
19
S
V
R
T
Fig. 6.c
Fig. 6.d
A
E
Fig. 6.e