AVENTICS | RCM | R402002349-BDL-001-AC
Technical data
11 Technical data
Table 9:
General data
Dimensions
Weight
Operating temperature
range
Storage temperature range –25 °C to +75 °C
Protection to EN 60529/
IEC529 (applies to sensors)
Mounting position
Working pressure
Compressed air quality
Table 10:
Standards and directives complied with
98/37 EC
The Machine Directive
89/336 EEC Electromagnetic compatibility (The EMC Directive).
Only for versions with sensors.
A "Declaration of Incorporation" for the cylinder and "Declaration of
Conformity" for the sensors can be ordered from AVENTICS.
Depend on configuration; see product
catalogue.
Depends on configuration; see product
catalogue.
–10 °C to +60 °C
IP 65. Alternatively IP 67 if sensors with a
threaded connector are used.
Any. If there is a risk of standing water, the
cylinder must be installed with the shuttle
downwards.
2 — 8 bar. RMC-HD and RMC-HE: 4 — 8 bar
To DIN ISO 8573-1, class 6, 4, 3 or lower
solid pollutants: ≤5 μm
≤3 °C
dew point:
≤1 mg/m
oil content: