4. Technical data

Range
Accuracy of the front beam (horizontal)
Accuracy of the perpendicular (horizontal) beam
en
Angle accuracy (horizontal)
Accuracy of the plumb beam
Self-levelling time (approx.)
Laser class: Class 2
Beam diameter
Self-leveling range
Automatic cut-out
Operating status indicator
Power supply
Battery life
Operating temperature range
Storage temperature
Dust and water spray protection (except battery
compartment)
Weight
Dimensions

5. Safety rules

5.1 Basic information concerning safety
In addition to the information relevant to safety
given in each of the sections of these operating
instructions, the following points must be strictly
observed at all times.
5.2 General safety rules
a) Do not render safety devices ineffective and do
not remove information and warning notices.
b) The laser visibility glasses have no protective
function and do not protect your eyes from laser
light. As the laser visibility glasses restrict color
vision, they should be worn only when working
with this tool and must not be worn while driving
a vehicle on a public road.
c) Keep laser tools out of reach of children.
14
Printed: 07.07.2013 | Doc-Nr: PUB / 5071513 / 000 / 00
30 m
Range depends on the brightness of ambient light.
Right of technical changes reserved.
Temperature 25°C: ±3 mm at 10 m ( / " at 30 ft)
Temperature 25°C: ±3 mm at 10 m ( / " at 30 ft)
Temperature 25°C: 90° ±60"
Temperature 25°C: ±3 mm at 10 m ( / " at 30 ft)
3 s
Temperature 25°C, Visible: 635 Nm
IEC 825 1:2003, EN 60825 01:2003,
CFR 21 § 1040 (FDA)
Temperature 25°C, Distance 5 m: 3 mm
Temperature 25°C, Distance 20 m: 12 mm
±5°
Activated after: 15 min
LED and laser beams
AA size batteries, Alkaline batteries: 4
Alkaline battery, Temperature 25°C
(+77°F): Min. 20 h
10 - 40°C (+14 °F to 104 °F)
20 - 63°C (-4 °F to 145 °F)
IP 54
IEC 529
Without batteries: 660 g
138 mm X 51 mm X 126 mm
d) Failure to follow the correct procedures when
opening the tool may cause emission of laser
radiation in excess of class 2. Have the tool
repaired only at a Hilti service center.
e) Do not open the casing of the tool.
f) Check the condition of the tool before use. If the
tool is found to be damaged, have it repaired at
a Hilti service center.
g) Check the accuracy of the tool before using it to
take measurements.
h) The tool must be checked at a Hilti service
center after it has been dropped or subjected to
other mechanical stresses.
i) When the tool is brought into a warm environ-
ment from very cold conditions, or vice-versa,
allow it to become acclimatized before use.