GAS CONNECTION
Important
Those authorised to carry out this opera-
tion must have experience acquired and
certified in the specific sector, must make
the connection to the proper standards,
and must comply with all the relevant regu-
lations and legislation. Once the connec-
tion has been made, before the appliance is
put into operation a general check must be
made to ensure there are no gas leaks.
To make the connection, connect the mains line to
the appliance's connection pipe, fitting a shut-off
tap (A), to allow the gas supply to be cut off when
necessary.
Important
The tap (A), not supplied with the appliance,
must be installed in an easily accessible
position and its status (on or off) must be
obvious at a glance.
CONNECTION OF FUME EXHAUST VENT
Important
Make the connection in compliance with
the relevant legal requirements, using ap-
propriate and recommended materials.
Connecting to a fan extractor hood
To carry out this operation, proceed as follows.
A
A
Important
The gas supply pipe must comply with the
national requirements in force and must be
periodically examined and replaced if ne-
cessary.
1 - Position the appliance underneath the hood (A)
(see diagram).
Important
The gas supply tap must open automatical-
ly when the fan of the extraction system is
switched on.
A
- 21 -
A
IDM-3960200230.tif
IDM-39603312400.tif
IT
GB
DE
FR
ES
English