Installing Linking Sections; Accurate Mowing Along Edges - Stihl RMI 632 P Manual De Instrucciones

Ocultar thumbs Ver también para RMI 632 P:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

English
To install a search loop in combination with an external
docking station:
1
a
► Install two search loops (1), each at a 90° angle on the left
and right side of the docking station.
► Keep a minimum clearance of a = 6.6 ft. (2 m) from the
docking station.
To install a search loop in combination with a corridor:
1
a
► Install two search loops (1) at an angle of 90° in the part
of the mowing area that can only be reached via a corridor.
► Keep a minimum clearance of a = 6.6 ft. (2 m) from the
corridor entrance.
40
1
a
1
a

11.9 Installing Linking Sections

A linking section links a secondary area to the primary
mowing area, e.g. a mowing area in front of and behind the
house that the iMow cannot travel to on its own. This allows
both mowing areas to be mowed automatically.
1
► Route the perimeter wire (1) parallel and close to one
another.
► Attach the linking section to the ground with a sufficient
number of wire stakes (2).

11.10 Accurate Mowing Along Edges

► Along high obstacles, route the perimeter wire with a
minimum clearance of 7.9 in. (20 cm) from the obstacle.
This buffer area will be left unmowed.
To reduce the buffer area which will be left unmowed, you
can lay edging stones or pavers around high obstacles, e.g.
walls.
11 Installing the Perimeter Wire
1
2
1
a
0478-131-3046-A

Publicidad

Capítulos

Tabla de contenido
loading