Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 118
8. Tighten and loosen the bolt once again to check that the deviation
does not exceed 0.05 mm (2 mils).
9. Repeat steps 7 to 9 for the remaining feet.
The soft foot is now checked and corrected. The alignment
operation can now continue with the measuring sequence as per
chapter 3.7.
5.2

Limited rotation

In some applications, limited space around the shaft coupling forbids
the rotation of the measuring units to the 9 or 3 o'clock position.
However there is still a possibility to perform the alignment as long as
the measuring units can rotate 180°.
Execute all preparation steps as per chapter 3.1 to 3.6.
Measuring sequence:
1. The display unit indicates that the measuring units should be placed
in the 9 o'clock position. Since you can't reach it, place the
measuring units in your start position (in our example 11 o'clock)
and
confirm the measurement by pressing the "next" button.
2. The display unit now indicates the measuring units should be placed
in the 3 o'clock position. Rotate the measuring units by 180° (in our
example to the 5 o'clock position) and
confirm the measurement.
3. Follow the circle symbol on the display and rotate the measuring
units to the 12 o'clock position. Confirm the measurement. You can
now complete the alignment following the instructions sequence as
per chapter 3.8.
TMEA 1P/2.5 / TMEA 1PEx
Shaft Alignment Tools
37

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Tmea 1pex

Tabla de contenido